Measurement of Glutathione (GSH) Using A Standard STEAM Sequence with Optimized (TE, TM) Parameters: Spectral Simulation, Phantom, and Human Experiments at 3T

نویسنده

  • S. Yang
چکیده

Fig.2. STEAM spectra (around 2.54 ppm) of GSH from phantom (black) and simulation (red) at the optimized (TE, TM) = (72 ms,73 ms). The spectrum from phantom was smoothed with a 5-Hz line broadening and the simulated spectrum was also smoothed to match the line width of the phantom spectrum. Measurement of Glutathione (GSH) Using A Standard STEAM Sequence with Optimized (TE, TM) Parameters: Spectral Simulation, Phantom, and Human Experiments at 3T

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Resolved Glutamate and/or Glutamine Using Optimized STEAM at 3T – A Verification Study by Phantom Experiments

designed in [2] for unobstructed Glu and Gln detection with chosen (TE, TM) regions in white boxes for phantom experiments. Fig. 2. In vitro STEAM spectra of Glu and Gln acquired at (72ms, 06 ms) and (84 ms, 58 ms) at 3T and multiplied with a filter to render them representative of typical in vivo line widths. Fig. 3. In vivo STEAM spectra acquired from a voxel including the ACC of a healthy vo...

متن کامل

Simultaneous Detection of Unobstructed Glutamate and Glutamine Using Standard STEAM with Optimized Sequence Parameters at 3, 4, 4.7, 7, and 9.4 Tesla - A Simulation Study

Fig. 2. Contour diagrams, in {TE, TM} parameter space, of the ultimate index calculated at (a) 3T, (b) 4T, (c) 4.7T, (d) 7T, and (e) 9.4T, normalized to the maximum in each data set. The maximum ultimate indices at individual magnetic fields are shown in (f). Fig. 3. STEAM spectra using the optimized sequence parameters at the five fields and the 3Tspectra at {10ms, 10ms} at bottom as a referen...

متن کامل

Reproducibility of phase rotation STEAM at 3T: focus on glutathione.

PURPOSE The purpose of this study was to determine the reproducibility of a very short echo time (TE) phase rotation stimulated echo acquisition mode (STEAM) sequence at 3T with a focus on the detection of glutathione. METHODS Ten healthy subjects were scanned on two separate visits. Spectra were acquired from voxels placed in the anterior and posterior cingulates. Reproducibility was assesse...

متن کامل

Simultaneous Quantification of γ-aminobutyric acid, Glutamate, and Glutamine at 3T

BACKGROUND: γ-Aminobutyric acid (GABA), glutamate (Glu) and glutamine (Gln) are three important neurochemicals comprising a tightly coupled spin system. The coupling of this system and their low concentrations in brain typically render GABA MRS-invisible and Glu/Gln indistinguishable (and represented as the composite peak Glx) on standard clinical PRESS scans. Investigations by Hu et al. [1] ha...

متن کامل

Relaxation Times of Human Skeletal Muscle Metabolites at 7T

Introduction: Single-voxel proton MR spectroscopy (SV-H-MRS) of human skeletal muscle at ultra high fields provides accurate quantitation of muscular metabolite concentration due to improved spectral resolution and high signal to noise ratio. Quantitative evaluation of relaxation times is extremely important for accurately quantifying metabolite concentration, optimizing measurement protocols i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008