Effectiveness of ATP bioluminescence to assess hospital cleaning: a review

نویسندگان

  • N. Nante
  • E. Ceriale
  • G. Messina
  • D. Lenzi
  • P. Manzi
چکیده

INTRODUCTION Contamination of hospital surfaces plays an important role in the transmission of several healthcare-associated microorganisms, therefore methods for evaluating hospital surfaces' cleaning gain particular importance. Among these, there are visual inspection, quantitative microbiology, fluorescent markers and adenosine triphosphate (ATP) bioluminescence. The latter seems to provide interesting features, detecting the presence of ATP on surface (as Relative Light Units, RLU), a proxy of organic matter and microbial contamination. Several studies have investigated the effectiveness of this technology; with this research, we aim to summarize the most significant results. METHODS A systematic review was conducted. The keywords (namely, "ATP", "bioluminescence", "hospital" and "surfaces") were searched in PubMed/MEDLINE and Scopus databases, in order to find relevant data, from January 2000 to October 2014. After the selection, we globally considered 27 articles. RESULTS Most of the studies were conducted in United Kingdom and in USA. Different threshold RLU benchmark values were identified by analyzed studies. Fourteen of these researches compared the ATP bioluminescence with microbiological methods, 11 identified a significant correlation between the two methods, although poor or not complete for 5. DISCUSSION ATP bioluminescence is not a standardized methodology: each tool has different benchmark values, not always clearly defined. At the moment, we can say that the technique could be used to assess, in real time, hospital surfaces where cleanliness is required, but not sterility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increasing influenza vaccination rates among hospital employees without a mandatory policy.

Rizvani R. Monitoring the effectiveness of hospital cleaning practices by use of adenosine triphosphate bioluminescence assay. Infect Control Hosp Epidemiol 2009;30:678-684. 7. Lewis T, Griffith C, Gallo M, Weinbren M. A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces. / Hosp Infect 2008;69:156-163. 8. Turner DE, Daugherity EK, Altier C, Maurer KJ. Eff...

متن کامل

Assessment of hospital daily cleaning practices using ATP bioluminescence in a developing country.

UNLABELLED Visual assessment of surfaces may not be enough to document the level of cleanliness in the hospital setting. It is necessary to introduce quantitative methods to document the results of this practice. OBJECTIVE To evaluate the efficacy of hospital terminal cleaning procedures, using an adenosine triphosphate (ATP) bioluminescence method in a teaching hospital. METHOD During 2008...

متن کامل

An ASAE Meeting Presentation AN INVESTIGATION OF ATP BIOLUMINESCENCE AND QUANTITATIVE BULK TANK CULTURES TO ASSESS CLEANLINESS OF MILKING MACHINES

A series of experiments were performed to evaluate the performance of experimental detergents. Initial assessment of cleaning efficacy was done using a standardized milk soil (whole milk inoculated with bacteria) sprayed onto stainless steel test chips and allowed to incubate. These test chips were cleaned under controlled conditions in the laboratory. The residual milk soil was assessed using ...

متن کامل

Measurement of Michaelis Constants for ATP and Mg2+ in Bioluminescence Reaction of Luciferase by a Home-Made Luminometer

Effects of ATP and Mg2+ concentrations on bioluminescence reaction of luciferase (Photinus pyralis) were investigated by home-made luminometer. The Michaelis constants of the enzyme for ATP and Mg2+ obtained from the Lineweaver-Burk graph, were 61.9 mM ±3.3 mM and 251.6mM ± 39.0mM...

متن کامل

Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method

Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2017