Evolution of External and Internal Implant to Abutment Connection
نویسندگان
چکیده
A study of the implant to abutment connection is of paramount importance as it is the primary determinant of the strength and stability of the implant supported restoration, which in turn determines the restoration’s prosthetic stability. Traditionally, the Branemark's external hexagon has been widely used but its significant complications like abutment screw loosening, rotational misfit at implant-abutment interface and microbial penetration have led to modification of the external hexagon and the development of the internal implant-abutment connections. This review describes the various implantabutment connections that have evolved overtime from the traditional external hexagon.
منابع مشابه
Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value
Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...
متن کاملAbutment fracture and the technique Used to Remove the fracture portion of the Abutmet: Case Report
Abstract This clinical report presents a case of abutment fracture, due to occlusal overload, occurred with an implant-supported restoration on right mandibular first molar of a female patient. After 6 months of prosthetic reconstruction implants, the patient returned to the clinic due to the loss of implant crown. The fractured fragment of the abutment with the screw protec...
متن کاملEffect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.
The mechanical performance of cemented or screw-retained implant-supported crowns with an internal or external configuration is yet to be understood. This in vitro study evaluated the effect of screw-retained and cement-retained prostheses on internal and external implant-abutment connections. Thereby, the reliability and failure modes of crowns were investigated. Eighty-four implants (Emfils; ...
متن کاملClinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کاملEffect of GapSeal® as a Sealing Material on Microgap and Microleakage at External Hexagon Implant Connections Following Cyclic Loading: An In Vitro Study
Background and Aim: The mismatch of the implant-abutment connection can produce instant stress and microleakage which result in mechanical and biological complications. This study aimed to investigate the influence of GapSeal® as a sealing material on the extent of microgap and microleakage at the external hexagon implant platform following cyclic loading. Materials and Methods: Sixteen implan...
متن کامل