Internal to external wavelength calibration

نویسنده

  • Kailash C. Sahu
چکیده

The spectra of Hen 1357 (the Stingray nebula) were used to check the internal to external wavelength calibration of the STIS first order CCD modes. The radial velocity of the Stingray nebula is known to high accuracy (< 1 km/sec) and the line with of the nebular line is very narrow (< 8 km/sec for the integrated nebula). Thus the observations of the Stingray nebula are ideal to check the internal to external wavelength calibration of the first order modes. The observations were taken in G430L and G750M modes using a 52 x 0.05 arcsec slit covering the wavelength range 2900 to 5700 A and 6295 to 6867 A, respectively. The observed wavelength range includes many nebular emission lines. The wavelengths of the nebular lines derived using the pipeline internal wavelength calibration were compared with the wavelengths derived from other ground based observations. In all cases, the wavelength match between the two is of the same order as the accuracy to which the line center can be measured. These results imply that there is no significant offset between the internal and external wavelength calibrations for these modes. The HDF-S QSO observations were also used for this test both for the first order and the Echelle modes. The results of the HDF-S QSO observations further confirm the above finding for the first order modes, and imply that there is no significant offset between the internal and external wavelength calibration for the Echelle modes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The HST/FOS Wavelength Scale

I analyze the accuracy of the FOS pipeline wavelength calibration for the FOS/RD detector with the G570H grating. I use observations of arc spectra and external targets that I obtained in the context of studies of galactic nuclei, complemented with an observation of the planetary nebula NGC 6833 obtained by the FOS Instrument Science Team. The combined data were obtained in five visits spread o...

متن کامل

Calibration Markers for Digital Templating in Total Hip Arthroplasty

Digital templating with external calibration markers is the standard method for planning total hip arthroplasty. We determined the geometrical basis of the magnification effect, compared magnification with external and internal calibration markers, and examined the influence on magnification of the position of the calibration markers, patient weight, and body mass index (BMI). A formula was der...

متن کامل

Design and establishment of a new calibration system traceable to the national standards

−47− Synthesiology English edition Vol.1 No.1 (2008) In the 1990s, a U.S. company developed a new infrared clinical thermometer in which measurement was taken by inserting the sensor probe into the ear canal (hereinafter will be called “ear thermometer”), and was marketed in the United States and Europe. Figure 1 shows the external appearance of ear thermometers and the schematic diagram of the...

متن کامل

Flux Calibration of the ACS CCD Cameras IV. Absolute Fluxes

ISRs I–III in this series define the charge transfer efficiency (CTE) for the CCD detectors, the encircled energy fractions, and the optical throughput degradation. This fourth ISR establishes the absolute flux calibration for the photometry, as corrected with the algorithms specified in I–III. Synthetic photometry from the SEDs of three primary hot 30,000–60,000K WDs define these sensitivity c...

متن کامل

Uncertainty evaluation and electronic improvements of a wavemeter to measure the wavelength of an external cavity diode laser

A Michelson wavemeter was developed to test the accuracy and give traceability to the wavelength of external cavity diode lasers. These lasers were stabilized using a Littrow configuration and an iodine gas cell as frequency reference, and they were used as light sources in the assembly of a new interferometric system for the gauge block calibration. Previously, a microcontroller counting devic...