Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures.

نویسندگان

  • Anoop C Dhamangaonkar
  • Deepak Joshi
  • Arvind B Goregaonkar
  • Akhil A Tawari
چکیده

PURPOSE To compare the outcome in patients who underwent surgery for unstable intertrochanteric femoral fractures using the proximal femoral locking plate versus the dynamic hip screw (DHS). METHODS 15 men and 5 women aged 32 to 78 (mean, 55) years were randomised to the proximal femoral locking plate group, whereas 14 men and 6 women aged 38 to 75 (mean, 59) years were randomised to the conventional 135-degree DHS group. The time to union, medialisation of the shaft, neck-shaft angle, limb shortening, varus collapse, and functional outcome (using the Hospital for Special Surgery Hip Rating System) were assessed. RESULTS Respectively in the locking plate and DHS groups, the mean times to union were 14.6 and 16.5 weeks (p=0.067) and the mean limb shortenings were 0.3 and 1.4 cm (p<0.001). Medialisation of the shaft occurred in 0 and 15 patients (p<0.0001); varus collapse occurred in 2 and 5 patients (p=0.408); the functional hip score was good-to-excellent in 18 and 11 patients (p=0.031); deep wound infection occurred in 3 and 2 patients; and implant cut-out occurred in one patient each group. CONCLUSION A non-collapsing locking plate achieved bone union in unstable intertrochanteric fractures with lower risks of limb shortening and medialisation of the shaft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Dynamic hip screw with locked plate VRS Proximal Femoral Nail for the management of intertrochanteric fracture: A comparative study

Dynamic hip screw has long been a standard implant for intertrochanteric hip fractures. The inception of intramedullary nails has further revolutionized their management. With a constant evolution in the designs of both these implants, there has always been a conflict concerning the superiority of one over the other. In this randomized prospective cohort study, 80 patients with intertrochanteri...

متن کامل

Letter to the editor: Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures.

To the Editor: We read with interest the article by Dhamangaonkar et al.1 May the authors clarify the following points. 1. A dynamic hip screw (DHS) with fixed angle locking screws reduces the risk of implant failure, particularly for patients with osteoporotic bone or less stable fracture configurations.2 Why did the authors compare a proximal femoral locking plate with a non-locking 135o DHS?...

متن کامل

Management Options and Treatment Algorithm in Intertrochanteric Fractures

Background: Intertrochanteric (IT) fractures are one of the most common lower limb fractures. There are many varied treatment options to treat the same. Also, our basic understanding of IT fractures is improving leading to evolution of newer concepts which in turn is leading to designing of newer implants. In this sea of newer treatment options, are all newer implants merely market driven? The ...

متن کامل

Unstable Intertrochanteric Fracture Fixation – Is Proximal Femoral Locked Compression Plate Better Than Dynamic Hip Screw Naiyer aSif1, SOhail ahmad2, OwaiS ahmad QureShi3, latif Zafar JilaNi4, taJdar hameSh5,

Background: Intertrochanteric fractures are one of the most common fractures encountered in our practice. Most of them need operative intervention and union is achieved. As per the literature dynamic hip screw (DHS) is the gold standard for the treatment of these fractures, however problem arises with maintenance of neck shaft angle and proper reduction in unstable intertrochanteric fractures. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2013