Determination of lomefloxacin, an antibacterial drug, in pharmaceutical preparations based on its polarographic catalytic wave in the presence of 2-iodoacetamide.
نویسندگان
چکیده
In a 0.125 mol/L phosphate (pH 6.6)/2.5 x 10(-4) mol/L 2-iodoacetamide solution, lomefloxacin yields a response of a polarographic catalytic current. The second-order derivative peak current of the catalytic wave of lomefloxacin is proportional to its concentration in the range of 1.0 x 10(-8)-1.0 x 10(-6) mol/L (r = 0.998). The sensitivity of the catalytic wave is 25-times higher than that of the corresponding reduction wave for 5.0 x 10(-7) mol/L lomefloxacin. The proposed method was applied to the determination of lomefloxacin in pharmaceutical preparations. The polarographic reduction wave is ascribed to a one-electron reduction of the C=C bond of lomefloxacin zwitterion accompanied by an acid-base equilibrium. The catalytic wave should be caused by regeneration of the lomefloxacin molecule at electrode surface due to the one-electron reduction product being further oxidized by electroreductive intermediate products of 2-iodoacetamide.
منابع مشابه
Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
متن کاملSquare Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...
متن کاملDetermination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
متن کاملSquare Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...
متن کاملPerformance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 17 10 شماره
صفحات -
تاریخ انتشار 2001