Comparison of red cell and whole blood volume as performed using both chromium-51-tagged red cells and iodine-125-tagged albumin and using I-131-tagged albumin and extrapolated red cell volume.

نویسندگان

  • Howard J Dworkin
  • Mary Premo
  • Stuart Dees
چکیده

BACKGROUND Our facility's current blood volume measurement protocol has involved separate measurement of plasma and red cell volumes. The purpose of this study is to determine whether measurement with a recently FDA-approved, one-compartment semiautomated system provides similar accuracy. METHODS Blood volume measurement was performed on 27 volunteers using our current protocol followed immediately by semiautomated plasma volume measurement and red cell volume calculation with a recently available system (BVA-100). RESULTS Double labeling for red cell mass and plasma volume required approximately 5 hours of technologist and processing time; measurement with the BVA-100 required approximately 1.5 hours or less, a saving of 3.5 hours time per test. Whole blood and red cell volume each exhibited a Pearson correlation of 0.96, and plasma volume exhibited a Spearman rank correlation of 0.90. Average percent difference between the measurement methods was 2.2% for whole blood volume, 0.9% for red cell volume, and 3.3% for plasma volume. The mean ratio between the mean body hematocrit and measured venous hematocrit (f ratio) was 0.91, with a standard deviation of 0.0405. CONCLUSIONS The BVA-100 has significant advantages in terms of time and ease of use. The 2 tests can be considered equivalent methods for blood volume measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evidence for a red cell shunting mechanism in the kidney.

Simultaneous tagged red cell and tagged plasma albumin concentration-time curves were obtained from the renal vein without recirculation, following rapid injection of the indicators into a renal artery. The mean transit time of the red cells was consistently faster than that of the plasma albumin, but the washout downslopes of the indicators was found to be identical. This is interpreted as ind...

متن کامل

Effect of endothelin on plasma volume and albumin escape.

Previous studies have demonstrated that endothelin-1 (ET-1) is a potent vasoconstrictor that decreases cardiac output and increases hematocrit. The present study was designed to determine if the rise in hematocrit and decrease in cardiac output are in part due to shifts of plasma from the vascular space to the interstitial space. Red blood cell volume and plasma volume were determined by using ...

متن کامل

Reduced cardiac volumes in chronic fatigue syndrome associate with plasma volume but not length of disease: a cohort study

OBJECTIVES To explore potential mechanisms that underpin the cardiac abnormalities seen in chronic fatigue syndrome (CFS) using non-invasive cardiac impedance, red cell mass and plasma volume measurements. METHODS Cardiac MR (MR) examinations were performed using 3 T Philips Intera Achieva scanner (Best, NL) in participants with CFS (Fukuda; n=47) and matched case-by-case controls. Total volu...

متن کامل

Application of a Seamless and Restriction Endonuclease-free Cloning Method to Produce Recombinant Full-length N-terminal His-tagged Streptolysin O in E.coli

Background and Aims: DNA cloning, sub-cloning and site directed mutagenesis are the most common strategies in nearly all projects of recombinant protein production. The classical method of restriction site cloning is unsatisfactory due to the need for supply of restriction enzymes and the inefficiency of the digestion reaction. Many new methods, including recombinatorial cloning and ligation in...

متن کامل

A critical evaluation of red cell and plasma volume techniques in patients with burns.

From the results in 110 patients, in whom 207 red cell volume estimations were made at various times after burning using either (51)Cr-, (32)P-, or Group NN-labelled cells, and 17 plasma volume estimations on the same patients using either T-1824-or (131)I-labelled albumin, it is concluded that: [List: see text]

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The American journal of the medical sciences

دوره 334 1  شماره 

صفحات  -

تاریخ انتشار 2007