Free-breathing multislice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence.

نویسندگان

  • Sebastian Weingärtner
  • Sébastien Roujol
  • Mehmet Akçakaya
  • Tamer A Basha
  • Reza Nezafat
چکیده

PURPOSE To develop a novel pulse sequence for free-breathing, multislice, native myocardial T1 mapping. METHODS The slice-interleaved T1 (STONE) sequence consists of multiple sets of single-shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only selectively excited once after each inversion pulse to allow sampling of the unperturbed longitudinal magnetization in the adjacent slices. For respiratory motion, a prospective slice-tracking respiratory navigator is used to decrease through-plane motion followed by a retrospective image registration to reduce in-plane motion. STONE T1 maps were calculated using both a two-parameter and three-parameter fit model. The accuracy and precision of the STONE sequence for different T1 , T2 , and inversion pulse efficiency were studied using numerical simulations and phantom experiments. T1 maps from 14 subjects were acquired with the STONE sequence and T1 s were compared to the MOdified Look-Locker Inversion recovery sequence (MOLLI). RESULTS In numerical simulations and phantom experiments, the STONE sequence using a two-parameter fit model yields more accurate T1 times compared to MOLLI, with similar high precision. The three-parameter fit model further improves the accuracy, but with a reduced precision. The native myocardial T1 times were higher in the STONE sequence using two- or three-parameter fit compared to MOLLI. The standard deviation of the T1 times was lower in the STONE T1 maps with a two-parameter fit compared with MOLLI or a three-parameter fit. CONCLUSION The STONE sequence allows accurate and precise quantification of native myocardial T1 times with the additional benefit of covering the entire ventricle. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of free-breathing multi-slice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence

Background Quantitative myocardial T1 mapping is a promising technique for assessment of interstitial diffuse fibrosis. Recently, a novel T1 mapping sequence for free-breathing, multi-slice, myocardial T1 mapping using the sliceinterleaved T1 (STONE) has been developed [1], which was shown to provide superior accuracy compared to MOLLI [2]. However, in-vivo reproducibility and precision of this...

متن کامل

Reproducibility of slice-interleaved T1 (STONE) mapping sequence

Background Slice interleaved T1 mapping sequence (STONE) allows quantification of native T1 of the entire ventricle in a single free-breathing scan. Using this sequence, data acquisition for different slices are interleaved, allowing longer recovery time after the inversion pulse, which could result in improved accuracy and precision. However, measurement reproducibility of the STONE sequence h...

متن کامل

Diffuse Myocardial Fibrosis detected by Multi-slice T1 Mapping using Slice Interleaved T1 (STONE) Sequence in Patients with Hypertrophic Cardiomyopathy

Background The presence of myocardial fibrosis is associated with worse clinical outcome in hypertrophic cardiomyopathy (HCM) patients. Due to the substantial variations in left ventricular (LV) wall thickness and fibrosis in HCM, volumetric coverage of entire LV myocardium is essential for the accurate assessment of myocardial fibrosis. Slice-interleaved T1 (STONE) mapping sequence allows for ...

متن کامل

Free-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging

Background Quantitative myocardial T1 mapping and extracellular volume fraction (ECV) show promise for non-invasive assessment of cardiomyopathies. Most available T1 mapping sequences use a single slice breath-hold acquisition with balanced steady state free precession (b-SSFP) readout [1]. However, b-SSFP readout is sensitive to B0 field inhomogeneity and is potentially T2 dependent [1]. In th...

متن کامل

Blood T1 measurements using slice-interleaved T1 mapping (STONE) sequence

Background Slice interleaved T1 (STONE) mapping sequence was recently proposed to take advantage of increased recovery time of spins to improve accuracy and precision of native myocardial T1 values. In this sequence, a nonselective inversion pulse is followed by acquisition of the data for different slices. Therefore, blood pool may experience different recovery time at different slice location...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره   شماره 

صفحات  -

تاریخ انتشار 2014