Comparison of ECV measurements during equilibrium between IR- and SR-based Cardiac T1Mapping
نویسندگان
چکیده
Background Cardiac T1 and extracellular volume fraction (ECV), derived from preand post-contrast cardiac and blood T1 measurements, are emerging imaging biomarkers of diffuse cardiac fibrosis. The most frequently used cardiac T1 mapping pulse sequence is MOLLI [1]. However, MOLLI is known to be sensitive to rapid heart rate and irregular rhythm, because it is based on inversion-recovery (IR) of magnetization preparation. In response, we developed an arrhythmia-insensitive-rapid (AIR) cardiac T1 mapping pulse sequence based on B1insensitive saturation-recovery (SR) of magnetization preparation [2]. Our prior study [2] showed that AIR (scan time = 2-3 heart beats) is faster and yields more accurate cardiac T1 measurements than MOLLI (scan time = 17 heart beats). We sought to compare ECV measurements between SR-based AIR and IR-based MOLLI cardiac T1 mapping at 3T.
منابع مشابه
Impact of Additional Transthoracic Electrical Cardioversion on Cardiac Function and Atrial Fibrillation Recurrence in Patients with Persistent Atrial Fibrillation Who Underwent Radiofrequency Catheter Ablation.
Backgrounds and Objective. During the procession of radiofrequency catheter ablation (RFCA) in persistent atrial fibrillation (AF), transthoracic electrical cardioversion (ECV) is required to terminate AF. The purpose of this study was to determine the impact of additional ECV on cardiac function and recurrence of AF. Methods and Results. Persistent AF patients received extensive encircling pul...
متن کاملCardiac T1 mapping in congenital heart disease: bolus versus infusion protocol for measurement of myocardial extracellular volume
Background Measurement of myocardial extracellular volume fraction (ECV) with T1 mapping cardiac magnetic resonance (CMR) before and after the application of a gadolinium-based extracellular contrast agent enables the assessment of diffuse myocardial fibrosis. The equilibrium between blood and myocardium contrast concentration required for ECV measurements can be achieved with a primed contrast...
متن کاملT1 mapping for myocardial extracellular volume measurement by CMR: bolus only versus primed infusion technique.
OBJECTIVES The aim of this study was to determine the accuracy of the contrast "bolus only" T1 mapping cardiac magnetic resonance (CMR) technique for measuring myocardial extracellular volume fraction (ECV). BACKGROUND Myocardial ECV can be measured with T1 mapping before and after contrast agent if the contrast agent distribution between blood/myocardium is at equilibrium. Equilibrium distri...
متن کاملEvaluation of changes in excision cavity volume during whole breast irradiation using secondary CT image
Background: The aim of this study was to evaluate the reduction in excision cavity volume (ECV) during the whole breast radiotherapy (WBRT). The delineating of reduced cavity volume on secondary CT (computed tomography) might decrease the field size of boost plan. Materials and Methods: Twenty patients were treated having breast conservative surgery. At first, primary CT simulation (CT-1) was d...
متن کاملMyocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI
BACKGROUND Myocardial T1-mapping recently emerged as a promising quantitative method for non-invasive tissue characterization in numerous cardiomyopathies. Commonly performed with an inversion-recovery (IR) magnetization preparation at 1.5T, the application at 3T has gained due to increased quantification precision. Alternatively, saturation-recovery (SR) T1-mapping has recently been introduced...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2014