The selective effect of optical defocus on detection and resolution acuity in peripheral vision.

نویسنده

  • R S Anderson
چکیده

Detection and resolution acuity was measured at 30 degrees in the periphery for sinusoidal gratings under differing amounts of optical defocus. Within the range -2.0 to +2.5 diopters defocus, detection acuity was higher than resolution acuity. As defocus increased, detection acuity decreased continuously but resolution acuity was little affected until around 2.0 diopters defocus. The results indicate that resolution performance is sampling limited in peripheral vision, even for significant refractive error, and is more robust than detection acuity to the effects of optical defocus.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short-wavelength acuity: optical factors affecting detection and resolution of blue–yellow sinusoidal gratings in foveal and peripheral vision

Previous studies have indicated that peripheral achromatic grating resolution is limited by the sampling density of the neural array (sampling limited), and largely unaffected by large amounts of optical defocus and significant changes in luminance. Under certain conditions, peripheral short-wavelength sensitive (SWS) grating acuity is also sampling limited. We wished to determine how the sampl...

متن کامل

Influence of optical defocus on peripheral vision.

PURPOSE Peripheral optical corrections are often thought to give few visual benefits beyond improved detection acuity. However, patients with central visual field loss seem to benefit from peripheral correction, and animal studies suggest a role for peripheral vision in the development of myopia. This study was conducted to bridge this gap by systematically studying the sensitivity to optical d...

متن کامل

Optical defocus: differential effects on size and contrast letter recognition thresholds.

PURPOSE To determine if optical defocus produces a greater reduction in visual acuity or small-letter contrast sensitivity. METHODS Letter charts were used to measure visual acuity and small-letter contrast sensitivity (20/25 Snellen equivalent) as a function of optical defocus. Letter size (acuity) and contrast (contrast sensitivity) were varied in equal logarithmic steps to make the task th...

متن کامل

The effect of optical defocus on the test-retest variability of visual acuity measurements.

PURPOSE To determine the effect of optical defocus on the test-retest variability (TRV) of visual acuity measurements in normal subjects. METHODS Normal subjects underwent repeated visual acuity measurement with optical defocus of 0, 0.50, and 1.00 D. All measurements were taken using the Early Treatment Diabetic Retinopathy Study (ETDRS) version of the Bailey-Lovie logMAR chart. TRV was quan...

متن کامل

Effect of window size on detection acuity and resolution acuity for sinusoidal gratings in central and peripheral vision.

Detection and resolution of square patches of sinusoidal gratings were measured in central and peripheral vision (30 degrees horizontal temporal visual field) for high-contrast gratings as a function of the number of cycles in the stimulus. We determined performance in a forced-choice paradigm for a fixed number of stimulus cycles by arranging for stimulus diameter to vary inversely with spatia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Current eye research

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 1996