An optimized strategy for real-time hemorrhage monitoring with electrical impedance tomography.
نویسندگان
چکیده
Delayed detection of an internal hemorrhage may result in serious disabilities and possibly death for a patient. Currently, there are no portable medical imaging instruments that are suitable for long-term monitoring of patients at risk of internal hemorrhage. Electrical impedance tomography (EIT) has the potential to monitor patients continuously as a novel functional image modality and instantly detect the occurrence of an internal hemorrhage. However, the low spatial resolution and high sensitivity to noise of this technique have limited its application in clinics. In addition, due to the circular boundary display mode used in current EIT images, it is difficult for clinicians to identify precisely which organ is bleeding using this technique. The aim of this study was to propose an optimized strategy for EIT reconstruction to promote the use of EIT for clinical studies, which mainly includes the use of anatomically accurate boundary shapes, rapid selection of optimal regularization parameters and image fusion of EIT and computed tomography images. The method was evaluated on retroperitoneal and intraperitoneal bleeding piglet data. Both traditional backprojection images and optimized images among different boundary shapes were reconstructed and compared. The experimental results demonstrated that EIT images with precise anatomical information can be reconstructed in which the image resolution and resistance to noise can be improved effectively.
منابع مشابه
Applications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملImprovement ability of EIT for Thermal monitoring during Thermal Therapy by gold nanoparticles
Introduction: To prevention the healthy tissues from irreversible damages, monitoring the temperature variation of healthy tissues is critical parameter during thermal therapies. Electrical impedance tomography (EIT) is considered as a real time imaging modality for monitoring the temperature but researches show that it suffers from low temperature resolution. In this study usi...
متن کاملFeasibility Study of Real-time and Automated Monitoring of Iranian Rivers using 50-kHz Fluvial Acoustic Tomography System
Acoustic Tomography (AT) technique is an innovative method for real-time river monitoring. In this study, not only the accuracy of flow velocity measurement using 50 kHz AT system which is appropriate for narrow rivers (most Iranian rivers) is evaluated, but also its performance is compared with 30 kHz one which is used in wide rivers. The comparison results showed that the velocity resolutions...
متن کاملUse of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review
Thoracic electrical impedance tomography is a real-time, noninvasive monitoring tool of the regional pulmonary ventilation distribution. Its bedside use in patients with acute respiratory distress syndrome has the potential to aid in alveolar recruitment maneuvers, which are often necessary in cases of refractory hypoxemia. In this case report, we describe the monitoring results and interpretat...
متن کاملMonitoring Steam-Assisted Gravity Drainage (SAGD) with EIT
Steam-assisted gravity drainage (SAGD) is a technique that has been developed to efficiently extract bitumen from deep reservoirs. We propose using electrical impedance tomography (EIT) for real-time monitoring of SAGD wells to maintain optimal operating conditions. Several electrode configurations along the pipelines and measurement strategies are presented and compared.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 32 5 شماره
صفحات -