The Quantification of Physiologically Relevant Cross-Shear Wear Phenomena on Orthopaedic Bearing Materials Using the MAX-Shear Wear Testing System

نویسندگان

  • Matthew R. Gevaert
  • Martine LaBerge
  • Jennifer M. Gordon
  • John D. DesJardins
چکیده

Background: The occurrence of multi-directional sliding motion between total knee replacement bearing surfaces is theorized to be a primary wear and failure mechanism of ultra-high molecular weight poly(ethylene) (UHMWPE). To better quantify the tribologic mechanisms of this cross-shear wear, the MAX-Shear wear-testing system was developed to evaluate candidate biomaterials under controlled conditions of cross-shear wear. Method of approach: A computer controlled traveling x-y stage under a 3 degree-offreedom statically loaded pin is used to implement the complex multi-directional motion pathways observed during TKR wear simulation. A MHz collection of dynamic x-y friction was available on all six environmentally controlled stations. The functionality of this testing platform was proven in a 100,000 cycle, 11.6 MPa, wear test using 15.0 mm diameter polished stainless steel spheres against flat GUR4150 UHMWPE. A five-pointed star wear pattern was used to incorporate the physiologically relevant cross-shear sliding conditions of stop/start, 50 mm /s entraining velocity and five crossing angles of 72°. Using normalized volumetric reconstruction of the resulting surface damage, a direct quantitative relationship between linear and cross-shear surface damage intensity was obtained. Results: Cross-shear surface damage volume loss was found to be 2.94 ± 0.88 times that associated with linear sliding under identical tribologic conditions. SEM analysis of linear wear damage showed consistent fibril orientation along the direction of sliding while cross-shear wear damage showed multi-directional fibril orientations and increased surface roughness. Significant increases in discrete crossing-point friction coefficients were recorded throughout testing. Conclusions: This scientific approach to quantifying the tribologic effects of cross-shear provides fundamental wear mechanism data that are critical in evaluating potential biomaterials for use as in vivo bearings. Relevant multi-axis, cross-shear wear testing is necessary to provide quantifiable measures of complex biomaterials wear phenomena. DOI: 10.1115/1.2000272

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester

BACKGROUND All-polymer bearings involving polyetheretherketone (PEEK) have been proposed for orthopaedic applications because they may reduce stress shielding, reduce weight of the implants, reduce wear and risk of osteolysis, and prevent release of metal ions by replacing the metal articulating components. Little is known about the biotribology of all-polymer PEEK bearings, including the effec...

متن کامل

What design factors influence wear behavior at the bearing surfaces in total joint replacements?

Bearing surface wear in total joint replacements arises from local stresses that exceed the mechanical strength of the articulating materials. Because both the tensile/compressive principal stresses and maximum shear stress near the bearing surface increase when contact stresses increase, minimizing contact stresses has been a central design goal, especially in total knees. Wear rates increase ...

متن کامل

The effect of insert conformity and material on total knee replacement wear

The mean average life is increasing; therefore, there is a need to increase the lifetime of the prostheses. To fulfil this requirement, new prosthetic designs and materials are being introduced. Two of the design parameters that may affect wear of total knee replacements, and hence the expected lifetime, are the insert conformity and material. Computational models have been used extensively for...

متن کامل

Influence of contact pressure, cross-shear and counterface material on the wear of PEEK and CFR-PEEK for orthopaedic applications

Total joint replacement is a successful surgical intervention for the treatment of the degeneration of many joints, particularly the hip and knee. As the demand for joint replacement grows, and the life expectancy of the population increases, the performance requirements of these implants also changes. New materials, to improve longevity and enhance performance have been explored including PEEK...

متن کامل

بررسی اثر نوع فیلر بر سایش سه جزئی کامپوزیت دندانی

Statement of Problem: The relatively poor wear resistance of dental composite in stress bearing posterior situations has restricted wider clinical application of this restorative material. Purpose: The aim of this study was to evaluate the three body abrasive wear of a dental composite based on a new filler (leucite: KAl Si2O6) and to compare it with the wear resistance of a composite based on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005