Time-resolved chemiluminescence technique for the microdetermination of proteins based on their complexation with copper(II).
نویسندگان
چکیده
Based on the complexation between proteins and Cu(II) coupled with the time-resolved chemiluminescence (CL) technique, a highly sensitive and quantitative assay for measuring proteins in solution is described. The complexes of proteins with Cu(II) have a strongly catalytic effect on the luminol-H2O2 CL reaction. Because the CL emission produced by the complexes is much more long-lived than that by Cu(II), the CL signals originating from proteins can be easily identified and measured with a time-resolved technique. On this basis, bovine albumin fraction V (BAF V) can be quantitatively determined in the range of 0.01 - 5.0 microg/ml with a detection limit of 5.8 ng/ml. The results show that the proposed assay exhibits a small variation in the response values for the same amount of different proteins, as compared to the Lowry as well as Bradford assays. The CL assay has also been studied for the detection of immobilized proteins.
منابع مشابه
Determination of polyamines by flow injection analysis with a chemiluminescence detector based on their complexation with copper(II).
Through the flow injection analysis experiments, we discovered that an unsaturated complex of Cu(II) and polyamines (spermine, spermidine, putrescine) had a strongly catalytic effect on luminol-H(2)O(2) chemiluminescence (CL) reaction, and that the CL intensity is proportional to the concentrations of polyamines. Based on the automatic formation of an unsaturated complex of polyamines and Cu(II...
متن کاملLectin affinity electrophoresis of alpha-fetoprotein detected by immunoenzymatic and chemiluminescent amplification followed by direct scanning.
Microdetermination of alpha-fetoprotein (AFP) glycoforms by lectin affinity electrophoresis followed by chemiluminescence reaction using horseradish peroxidase (POD) or alkaline phosphatase (ALP) in antibody-affinity blotting was developed. The intensity of chemiluminescence obtained by ALP was greater than that by POD; however, the coefficient of variation with POD was less than that with ALP....
متن کاملSelective Cloud Point Extraction and Preconcentration of Copper by the Use of Dithizone as a Complexing Agent
The aim of this work was to develop a selective cloud point extraction method for the separation and preconcentration of copper(II) prior to spectrophotometric determination. For this purpose dithizone was used as a complexing agent and the experimental solution was acidified with sulfuric acid. Triton X-114 was used as a surfactant and after phase separation, based on the cloud point of th...
متن کاملIon-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کاملComparison of Stability Cu(C7H3NO4)2 and Valance / Charge Ratio of Oxygen and Carbon atoms in the Complex by Changing the Vinyl, Acetylene, isopropil
In the complex (bispyridine -2 and 6-dicarboxylate copper II)) at position H number 26 with modifications of ligands such as vinyl, acetylene and isopropyl, changes in the valance / charge ratio for oxygen and carbon atoms in these complexes have been investigated by methods Initial calculations (ab initio) have been performed at two levels of HF, DFT. Finally, their stability is compared with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 9 شماره
صفحات -
تاریخ انتشار 2004