Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI

نویسندگان

  • Jochen von Spiczak
  • Gerard Crelier
  • Daniel Giese
  • Sebastian Kozerke
  • David Maintz
  • Alexander Christian Bunck
  • Lakshmi Prasad Dasi
چکیده

INTRODUCTION Phase contrast MRI allows for the examination of complex hemodynamics in the heart and adjacent great vessels. Vortex flow patterns seem to play an important role in certain vascular pathologies. We propose two- and three-dimensional metrics for the objective quantification of aortic vortex blood flow in 4D phase contrast MRI. MATERIALS AND METHODS For two-dimensional vorticity assessment, a standardized set of 6 regions-of-interest (ROIs) was defined throughout the course of the aorta. For each ROI, a heatmap of time-resolved vorticity values [Formula: see text] was computed. Evolution of minimum, maximum, and average values as well as opposing rotational flow components were analyzed. For three-dimensional analysis, vortex core detection was implemented combining the predictor-corrector method with λ2 correction. Strength, elongation, and radial expansion of the detected vortex core were recorded over time. All methods were applied to 4D flow MRI datasets of 9 healthy subjects, 2 patients with mildly dilated aorta, and 1 patient with aortic aneurysm. RESULTS Vorticity quantification in the 6 standardized ROIs enabled the description of physiological vortex flow in the healthy aorta. Helical flow developed early in the ascending aorta (absolute vorticity = 166.4±86.4 s-1 at 12% of cardiac cycle) followed by maximum values in mid-systole in the aortic arch (240.1±45.2 s-1 at 16%). Strength, elongation, and radial expansion of 3D vortex cores escalated in early systole, reaching a peak in mid systole (strength = 241.2±30.7 s-1 at 17%, elongation = 65.1±34.6 mm at 18%, expansion = 80.1±48.8 mm2 at 20%), before all three parameters similarly decreased to overall low values in diastole. Flow patterns were considerably altered in patient data: Vortex flow developed late in mid/end-systole close to the aortic bulb and no physiological helix was found in the aortic arch. CONCLUSIONS We have introduced objective measures for quantification of vortical flow in 4D phase contrast MRI. Vortex blood flow in the thoracic aorta could be consistently described in all healthy volunteers. In patient data, pathologically altered vortex flow was observed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of aortic coarctation with 4D flow MR imaging.

PURPOSE To show that 4D Flow is a clinically viable tool for evaluation of collateral blood flow and demonstration of distorted blood flow patterns in patients with treated and untreated aortic coarctation. MATERIALS AND METHODS Time-resolved, 3D phase contrast magnetic resonance imaging (MRI) (4D Flow) was used to assess blood flow in the thoracic aorta of 34 individuals: 26 patients with co...

متن کامل

4D flow imaging with MRI.

Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiovascular disease. Since its introduction in the late 1980s, 2-dimensional phase contrast MRI (2D PC-MRI) has become a routine part of standard-of-care cardiac MRI for the assessment of regional blood flow in the heart and great vessels. More recently, time-resolved PC-MRI with veloci...

متن کامل

Sub-8-minute cardiac four dimensional flow MRI using kat ARC and variable density signal averaging

Background Recently, 3D CINE phase-contrast MRI (4D Flow) has demonstrated potential for quantitative measurement of blood flow of the cardiovascular systems in the entire thoracic trunk [1]. However, the needs of 4D flow for high resolution, large volume coverage & respiratory gating render very long scan time. This work intended to improve the data acquisition efficiency of free-breathing car...

متن کامل

Improved assessment of aortic 3D blood flow with combined k-t accelerated 3D CINE bSSFP & 4D flow MRI

Background To determine hemodynamic parameters from 4D flow MRI, vessel boundaries are typically depicted by calculating a 3D phase contrast MR angiogram (PC-MRA) from 4D flow magnitude and flow images. However, this approach is limited by 1) low blood-tissue contrast of the magnitude images and 2) velocity weighting of PC-MRA may not fully depict areas of slow or swirling (vortex) flow. As a r...

متن کامل

Blood flow pattern in the ascending aorta after TAVI and conventional aortic valve replacement: Analysis using 4D-Flow MRI

Background Transarterial aortic valve implantation (TAVI) is a valid alternative to treat aortic stenosis in patients with high surgical risk. The impact of TAVI on changes in blood flow dynamics in the ascending aorta has not been systematically analyzed. Using temporally resolved, three-dimensional, phase contrast MRI (4D-flow), we studied 3D hemodynamics in the ascending aorta (AAo) after TA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015