X-ray energy dependence of the properties of the focused beams produced by polycapillary X-ray lens.
نویسندگان
چکیده
We investigated X-ray energy distribution in an X-ray microbeam produced by a polycapillary X-ray lens in combination with a sealed-type X-ray tube. This polycapillary X-ray lens has an output focal distance (OFD) of approximately 15 mm. The size of the X-ray microbeam and its OFD were estimated by using a wire scanning method. In our case, the sizes of the X-ray microbeams at the output focal distance were 49 microm for Mo L(alpha), 36 microm for W L(alpha), and 28 microm for Mo K(alpha). The spot sizes depend on the energy of the X-ray fluorescence. The reason for the energy dependence is that X-ray capillary optics is based on the principle of propagation through glass capillaries by means of X-ray total external reflection. The evaluated OFD values of Mo L(alpha) and Mo K(alpha) were slightly changed in 17 microm. However, a deviation of 100 microm from the OFD caused only a 3% increase of the focal spot size. Therefore, we concluded that the OFD showed no significant dependence on X-ray energy.
منابع مشابه
Polycapillary X-ray optics for microdiffraction
Polycapillary optics, i.e. shaped arrays consisting of hundreds of thousands of hollow glass capillary tubes, can be used to redirect, collimate or focus X-ray beams. X-rays emitted over a large angular range from conventional laboratory-based sources can be transformed into a beam with a small angular divergence or focused onto a small sample or sample area. Convergent beams of X-rays, with co...
متن کاملMO-A-213AB-01: Potential for Focused Low Energy X-Ray Beam for Therapy.
PURPOSE Megavoltage photon beams are typically used for therapy because of their skin sparing effect. However, a focused low-energy x-ray beam would also be skin sparing, and would have a higher dose concentration at the focal spot. Such a beam can be produced with polycapillary optics. MCNP5 was used to model dose profiles for a scanned focused beam, using measured beam parameters. The potenti...
متن کاملMeasurements and simulations of focused beam for orthovoltage therapy.
PURPOSE Megavoltage photon beams are typically used for therapy because of their skin-sparing effect. However, a focused low-energy x-ray beam would also be skin sparing, and would have a higher dose concentration at the focal spot. Such a beam can be produced with polycapillary optics. MCNP5 was used to model dose profiles for a scanned focused beam, using measured beam parameters. The potenti...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملOptimum driving a Z-pinch for soft X-Ray lasers
A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 24 7 شماره
صفحات -
تاریخ انتشار 2008