Simulation of the space charge near coronating conductors of ac overhead transmission lines
نویسنده
چکیده
In the case of ac high voltage overhead transmission lines, corona discharges may result in a broadband crackling and a humming noise at twice the mains frequency (2f ). The computation of the emitted 2f -levels presupposes the knowledge of the apparent power and force passed by the ions to the gas in the surroundings of the conductors. In this paper a simulation determining these magnitudes used in a previous publication is presented. For that purpose the ideas of earlier publications by other authors to compute corona losses are followed. Their central idea is to define an onset field strength on the surface of the conductor which is not exceeded by injecting the right amount of charges in the vicinity of the conductor. This injection together with the recombination determines the amount of drifting ions. The novelty of the method applied in this work is the consideration of different onset field strengths over the conductor surface in dependence of the polar angle. Further 2f -force and 2f -power acting on the gas in the vicinity of the conductor are determined out of the resulting ion drift. The corona currents thus computed coincide fairly well with measured results.
منابع مشابه
Simulation of Single Conductors Galloping Oscillations and Estimation of their Maximum Amplitudes
Overhead transmission lines are influenced by different factors which are mostly electrical and mechanical. These factors can cause problems for lines, distortions in network and outage of line. In designing transmission lines mechanical properties are evaluated after selecting a suitable conductor and clearance with regard to electrical properties. In lines designing, an important mechanical p...
متن کاملSimulation of Single Conductors Galloping Oscillations and Estimation of their Maximum Amplitudes
Overhead transmission lines are influenced by different factors which are mostly electrical and mechanical. These factors can cause problems for lines, distortions in network and outage of line. In designing transmission lines mechanical properties are evaluated after selecting a suitable conductor and clearance with regard to electrical properties. In lines designing, an important mechanical p...
متن کاملDC ion-currents in AC conductors in hybrid AC/DC transmission
This publication presents the results of a series of laboratory investigations on the DC ion current coupling between nearby AC and DC conductors, which is an important consideration in the design of hybrid AC/DC transmission towers. The corona activity depends on the surface condition of the conductor. Whether or not the conductors produced corona was controlled by selectively wetting them. Th...
متن کاملFinite Element Simulation of Ion Currents from Coronating Hvdc Overhead Lines
Abstract: Today's need for transmission capacity is continuously growing. As it is difficult to obtain new rights-of-way, options such as replacing existing ACby DC-lines to maximize the power capability of existing corridors are required. So as to limit land use, overhead transmission lines have been built as multi-circuit AClines on the same structure in many countries. Changing one AC circui...
متن کاملEnhanced Loadability of Existing Ehvac Line by Combined Ac-dc Transmission System
Now-a-days, demand for electric power has shown steady but geographically uneven growth.The wheeling of the available energy through existing long ac lines to load centers has a certain upper limit due to stability considerations. Thermal limit is the major limit to be considered while increasing loadability of existing EHV long transmission lines. Thus, these lines cannot be loaded to their th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011