An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.

نویسندگان

  • Tugberk Arda
  • Ayla Arikan
چکیده

STATEMENT OF PROBLEM The use of metal clasps on anterior teeth may cause esthetic problems. Recently, acetal resins have been used as an alternative tooth-colored denture clasp material to improve esthetics. However, there are few studies to support acetal resin use. PURPOSE The purpose of this in vitro study was to compare the retentive force and deformation of acetal resin and cobalt-chromium clasps after 36 months of simulated clinical use. MATERIAL AND METHODS Forty clasps each of acetal resin (1.2 or 2.0 mm thick) and cobalt-chromium (Dentorium)(1.2 mm thick) were fabricated using half-round standard prefabricated clasp patterns. The groups were further subdivided (n=10) into the type of tooth (premolar or molar metal model) and undercut (0.25 mm or 0.50 mm). The retentive force of the clasps was measured in distilled water by a specially designed insertion-removal testing apparatus with intervals corresponding to 0, 6, 12, 18, 24, 30, and 36 months of simulated clinical use of a removable partial denture. The distance between the clasp tips (mm) was measured with a microscope before and after the insertion-removal testing procedure. Comparison of the mean values of the retentive force (gram force) of the clasps and the distance (mm) between the clasp tips was conducted with 3-way analysis of variance and a Least Significant Difference (LSD) multiple range test (alpha=.05). RESULTS The mean values of tensile load required to dislodge acetal resin clasps with 1.2-mm thickness (111.6 g or 0.11 N) and with 2.0-mm thickness (178.4 g or 1.75 N) was significantly lower than that to dislodge Co-Cr clasps (694.1 g or 6.81 N) (P<.001). The retentive force needed to dislodge all 3 types of clasps was significantly lower for the molar than premolar models and also lower for the models with 0.25-mm undercuts than for those with 0.50-mm undercuts (P<.001). After 36 months of simulated clinical use, there was evidence of deformation in the cobalt-chromium clasps but no deformation noted for the acetal resin clasps. The retentive force of cobalt-chromium clasps (297.4 g or 2.91 N) after deformation remained significantly higher (P<.001) than the retentive force of acetal resin clasps that were 1.2 mm (110.7 g or 1.08 N) and 2.0 mm thick (177.5 g or 1.74 N), respectively. CONCLUSION Within the limitations of this study, the results suggest that both thicknesses of acetal resin clasps evaluated required less force for insertion and removal than Co-Cr clasps over a simulated 36-month period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexibility of the Retentive Arm of Acetal Resin Clasp versus Cast Clasps- an in Vitro Study

Restoration of esthetics is an important factor to consider in the fabrication of a removable partial denture (RPD) . 1 Several types of polymers and metal alloys have been used in RPD construction. Frequently, RPD clasps made from the same alloy as the metal framework. The most common alloys used for clasps are cobalt-chromium (Co-Cr) alloy and gold and titanium alloys, although these may be u...

متن کامل

Comparison between Acetal Resin and Cobalt-chromium Removable Partial Denture Clasps: Effect on Abutment Teeth

Fabricating an esthetically pleasing removable partial denture while avoiding the unsightly display associated with conventional clasp assemblies presented a challenge to dentists. Among other techniques, this could be done using acetal resin clasps as simple and effective means of improving removable partial denture esthetics.1 Patients often cite lack of retention and poor esthetics as reason...

متن کامل

Retentive forces and fatigue resistance of thermoplastic resin clasps.

OBJECTIVES The objective of this study was to evaluate the retentive force of clasps made from three thermoplastic resins and cobalt-chromium (CoCr) alloy by the insertion/removal test simulating 10 years use. METHODS On standardized premolar metal crowns 112 clasps were fabricated, including 16 CoCr (1.0 mm thick) clasps and 32 clasps (1.0 or 1.5 mm thick) from each of the following thermopl...

متن کامل

Retention Strength of Cobalt-Chromium vs Nickel-Chromium Titanium vs CP Titanium in a Cast Framework Association

Aim: There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and consi...

متن کامل

The abrasion of dental composite by cobalt-chromium clasps.

In cases where there are no suitable natural undercuts on the teeth which can be used to provide clasp retention for a partial denture artificial undercuts can be created by the application of a composite filling material. An in-vitro investigation was undertaken to assess the surface integrity of three different composite restorative materials following repeated cycles of movement of cobalt-ch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 94 3  شماره 

صفحات  -

تاریخ انتشار 2005