Implantable wireless battery recharging system for bladder pressure chronic monitoring.

نویسندگان

  • Darrin J Young
  • Peng Cong
  • Michael A Suster
  • Margot Damaser
چکیده

This paper presents an implantable wireless battery recharging system design for bladder pressure chronic monitoring. The wireless recharging system consists of an external 15 cm-diameter 6-turn powering coil and a silicone-encapsulated implantable rectangular coil with a dimension of 7 mm × 17 mm × 2.5 mm and 18 turns, which further encloses a 3 mm-diameter and 12 mm-long rechargeable battery, two ferrite rods, an ASIC, and a tuning capacitor. For a constant recharging current of 100 μA, an RF power of 700 μW needs to be coupled into the implantable module through the tuned coils. Analyses and experiments confirm that with the two coils aligned coaxially or with a 6 cm axial offset and a tilting angle of 30°, an external power of 3.5 W or 10 W is required, respectively, at an optimal frequency of 3 MHz to cover a large implant depth of 20 cm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MEMS-based Implantable Drug Delivery System

Implantable devices are currently used regularly for chronic pain relief, cardiac pacemakers, arterial infusion for cancer and insulin delivery. A MEMS based implantable drug delivery system (IDDS) integrating a subcutaneous reservoir, an in plane silicon pump and associated circuitry for local or centralized delivery of therapeutic agents for chemotherapy is proposed. System configurations, fl...

متن کامل

In-Vivo Implantable Sensor System for Measuring Bladder Wall Movements

The design and implementation of a medical implantable device for bladder monitoring is presented. A network of accelerometers is to be implanted in-between the outside bladder muscle and the mucous membrane. A pressure sensor is also implanted in this submucosal layer to obtain intraluminal pressure readings. The sensor system is powered by an implanted battery and provides a wireless communic...

متن کامل

An implantable ZigBee ready telemetric platform for in vivo monitoring of physiological parameters

This paper presents a multiple channel, bidirectional and implantable biotelemetric platform, suitable for real time in vivo monitoring of several physiological parameters. This system consists of an implantable unit, an external host and a user terminal. The ZigBee wireless technology, functioning as telemetric link, enables long battery lifetime and offers the opportunity to build up complex ...

متن کامل

Energy Efficient Approach for Solar Energy Harvesting in Wireless Sensor Network

The wireless sensor network is the self configuring type of network which is used to sense the environment conditions like temperature, pressure etc. The sensor network is deployed in the far places like forests; deserts. The sensor nodes have limited size and limited battery life. It is very difficult to recharge or replace the battery. The solar energy harvesting is the approach through which...

متن کامل

Design Challenges of Implantable Pressure Monitoring System

Pressure in various organs and body parts, such as blood vessels, heart, brain, eyes, bladder and GI tracts, is an important indication of health. Long term, continuous pressure monitoring is critically needed for a number of applications. When combined with existing neuro-prosthetics devices, they may provide better solutions to many neural disorders. First efforts toward a long-term implantab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Lab on a chip

دوره 15 22  شماره 

صفحات  -

تاریخ انتشار 2015