Primary Stability of Temporary Screws after Dentary and Orthopedic Forces under Static and Dynamic Load Cycles
نویسندگان
چکیده
The objective was to analyze the influence of dentary and orthopedic forces under static and dynamic loads in temporary screw stability. Self-drilling titanium (Ti6Al4V) screws (6 × 1.5 mm) were inserted and removed from pig ribs. Screws were loaded by static loads of 2 N and 5 N for 5 weeks. Dynamic force was applied during 56,000 cycles for simulations of a patient’s opening–closing mouth movements. Dynamic applied loads ranged from 2 to 5 N and from 5 to 7 N under a frequency of 1 Hz. Torque peak values at placement and removal were measured before and after static and dynamic cycles. Similarities in torque peaks (p = 0.3139) were identified at placement (12.54 Ncm) and removal (11.2 Ncm) of screws after a static load of 2 N. Statistical comparisons showed significant stability loss after dynamic cycles under loads of 2 N (64.82% at p = 0.0005) and 5 N (64.63% at p = 0.0026). Limited stability loss occurred in temporary screws submitted to 2 N static forces (p = 0.3139). The detrimental effects of dynamic cycles in temporary screws stability was attested after the simulation of dentary and skeletal forces, being intermittent forces more relevant in the loss of mechanical stability.
منابع مشابه
Effect of shell axial deformation on flutter of cantilevered cylindrical shells under follower forces
Axial vibration effect of shell particles on dynamic stability of a cantilevered cylindrical shell under an axial follower force was addressed. In spite of free-ended shells, the reduced axial force under this effect cannot be derived analytically. Instead, an approximate method was proposed based on the fact that the static (and harmonic) axial deformation under an axial load in a free-ended b...
متن کاملFirst Carpometacarpal Joint Dislocation and Review of Literatures
Dislocation of the first carpometacarpal (CMC) is a rare occurrence. Treatment of this dislocation varies from closed reduction and casting to ligament repair. Neglected dislocation or incomplete reduction of the 1st CMC cause chronic instability and painful arthritis, muscle imbalance and decreased grip force. In our study 6 patients is evaluated that were visited in less than 24 hours from ...
متن کاملBiomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
BACKGROUND As several new tibial osteotomy plates recently appeared on the market, the aim of the present study was to compare mechanical static and fatigue strength of three newly designed plates with gold standard plates for the treatment of medial knee joint osteoarthritis. METHODS Sixteen fourth-generation tibial bone composites underwent a medial open-wedge high tibial osteotomy (HTO) ac...
متن کاملتعیین مناسب ترین الگوی توزیع تنش (به روش اجزا محدود) در روشهای ثابت نمودن با پیچ قابل جذب پس از جراحی ساژیتال دو طرفه راموس
Background and Aim: Due to the complications associated with fixation by Titanium screws and plates in Bilateral Sagittal Split Ramus Osteotomy (BSSRO) surgery, the use of resorbable polymers has been increasingly recommended. Since there are not enough studies on this issue, this study aimed to assess the most appropriate stress distribution in fixation with resorbable screws after BSSRO surge...
متن کاملDynamic Stability of Nano FGM Beam Using Timoshenko Theory
Based on the nonlocal Timoshenko beam theory, the dynamic stability of functionally gradded (FG) nanoeams under axial load is studied in thermal environment, with considering surface effect. It is used power law distribution for FGM and the surface stress effects are considered based on Gurtin-Murdoch continuum theory. Using Von Karman geometric nonlinearity, governing equations are derived bas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017