Fast enantiomeric separation of uniconazole and diniconazole by electrokinetic chromatography using an anionic cyclodextrin: application to the determination of analyte-selector apparent binding constants for enantiomers.

نویسندگان

  • Y Martín-Biosca
  • C García-Ruiz
  • M L Marina
چکیده

The enantiomeric resolution of the fungicides uniconazole and diniconazole was performed using electrokinetic chromatography with cyclodextrins as pseudostationary phase (CD-EKC). A systematic evaluation of several chiral selectors was made. The anionic derivative carboxymethylated-gamma-cyclodextrin (CM-gamma-CD) was found to be the most appropriate for the enantioseparation of fungicides among all cyclodextrins tested. The influence of some experimental conditions such as nature and buffer pH, chiral selector concentration, and temperature on the enantiomeric separation of the compounds studied was also investigated. The use of a 50 mM phosphate buffer (pH 6.5) containing 5 mM CM-gamma-CD and a temperature of 50 degrees C enabled the baseline enantioresolution of mixtures of uniconazole and diniconazole in less than 5 min. In addition, apparent binding constants for each enantiomer-CM-gamma-CD pair at several temperatures, as well as thermodynamic parameters for binding were calculated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

متن کامل

Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

متن کامل

Rapid enantiomeric separation of polychlorinated biphenyls by electrokinetic chromatography using mixtures of neutral and charged cyclodextrin derivatives.

Electrokinetic chromatography with cyclodextrin derivatives (CD-EKC) was used to achieve the rapid enantiomeric separation of chiral polychlorinated biphenyls (PCBs). Thirteen of the 19 chiral PCBs stable at room temperature were individually separated into their two enantiomers by using 2-morpholinoethanesulfonic acid (MES) buffer (pH 6.5) containing carboxymethylated gamma-cyclodextrin (CM-ga...

متن کامل

Enantiomeric separation and determination of the enantiomeric impurity of armodafinil by capillary electrophoresis with sulfobutyl ether-β-cyclodextrin as chiral selector.

A selective capillary electrophoresis method using sulfobutyl ether-β-cyclodextrin as a chiral selector was developed and validated for the determination of the enantiomeric impurity of (R)-modafinil, i.e., armodafinil. Several parameters were optimized for a satisfactory enantioresolution, including the type and concentration of chiral selector and organic modifier, pH of background electrolyt...

متن کامل

Quantitative analysis of three chiral pesticide enantiomers by high-performance column liquid chromatography.

Methods for the enantiomeric quantitative determination of 3 chiral pesticides, paclobutrazol, myclobutanil, and uniconazole, and their residues in soil and water are reported. An effective chiral high-performance liquid chromatographic (HPLC)-UV method using an amylose-tris(3,5-dimethylphenylcarbamate; AD) column was developed for resolving the enantiomers and quantitative determination. The e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Electrophoresis

دوره 21 15  شماره 

صفحات  -

تاریخ انتشار 2000