Dynamic Behavior and Microstructural Properties of Cancellous Bone

نویسندگان

  • S. Laporte
  • F. David
  • V. Bousson
  • S. Pattofatto
چکیده

The aim of the presented study is to identify some properties of the dynamic behavior of the cancellous bone and to identify the link between this mechanical behavior and the microstructural properties. 7 cylinders of bovine cancellous bone (diameter 41 mm, thickness 14 mm) were tested in quasi static loading (0.001 s), 8 in dynamic loading (1000 s) and 10 in dynamic loading (1500 s) with a confinement system. All the specimens were submitted to imaging before the tests (pQCT) in order to indentify two microstructural properties: Bone Volume / Total Volume – BV/TV – and Trabeculae Thickness – Tb.Th. The behavior of bovine cancellous bone under compression exhibits a foam-type behavior over the whole range of strain rates explored in this study. The results show that for the quasistatic tests only the stresses are correlated with BV/TV. For the unconfined dynamic tests, the yield stress is correlated to BV/TV and the plateau stress to BV/TV and Tb.Th. For the confined tests, only the plateau stress is correlated to BV/TV and Tb.Th. The effect of strain rate is an increase of the yield stress and the plateau stress. The confinement has an effect on the measured values of compression stresses that confirms the importance of marrow flow in the overall behavior.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mutual associations among microstructural, physical and mechanical properties of human cancellous bone.

Previous studies have shown that low-density, rod-like trabecular structures develop in regions of low stress, whereas high-density, plate-like trabecular structures are found in regions of high stress. This phenomenon suggests that there may be a close relationship between the type of trabecular structure and mechanical properties. In this study, 160 cancellous bone specimens were produced fro...

متن کامل

Variability of trabecular microstructure is age-, gender-, race- and anatomic site-dependent and affects stiffness and stress distribution properties of human vertebral cancellous bone.

Cancellous bone microstructure is an important determinant of the mechanical integrity of vertebrae. The numerous microstructural parameters that have been studied extensively are generally represented as a single value obtained as an average over a sample. The range of the intra-sample variability of cancellous microstructure and its effect on the mechanical properties of bone are less well-un...

متن کامل

Functional dependence of cancellous bone shear properties on trabecular microstructure evaluated using time-lapsed micro-computed tomographic imaging and torsion testing.

When compressed axially, cancellous bone often fails at an oblique angle along well-defined bands, highlighting the importance of cancellous bone shear properties. Torsion testing to determine shear properties of cancellous bone has often been conducted under conditions appropriate only for axisymmetric specimens comprised of homogeneous and isotropic materials. However, most cancellous bone sp...

متن کامل

Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis.

We obtained medial and lateral subchondral cancellous bone specimens from ten human post-mortem proximal tibiae with early osteoarthritis (OA) and ten normal age- and gender-matched proximal tibiae. The specimens were scanned by micro-CT and the three-dimensional microstructural properties were quantified. Medial OA cancellous bone was significantly thicker and markedly plate-like, but lower in...

متن کامل

A comparison of the fatigue behavior of human trabecular and cortical bone tissue.

The fatigue properties of trabecular bone tissue (single trabeculae) and similarly sized cortical bone specimens from human tibia were experimentally determined on a microstructural level using four-point bending cyclic tests, and they were compared based on modulus, mineral density, and microstructural characteristics. The results showed that trabecular specimens had significantly lower moduli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009