A Chemical Ionization Mass Spectrometer for Ambient Measurements of Ammonia

نویسندگان

  • D. R. Benson
  • A. Markovich
  • M. Al-Refai
  • Shan-Hu Lee
  • S.-H. Lee
چکیده

This study presents a chemical ionization mass spectrometer (CIMS) for fast response, in-situ measurements of gas phase ammonia (NH3). The NH3 background level detected with the CIMS ranged between 0.3–1 ppbv, with an uncertainty of 30 pptv under optimized conditions. The instrument sensitivity varied from 4–25 Hz/pptv for >1 MHz of reagent ion signals (protonated ethanol ions), with a 30% uncertainty estimated based on variability in calibration signals. The CIMS detection limit for NH3 was ∼60 pptv at a 1 min integration time (3 sigma). The CIMS time response was <30 s. This new NH3-CIMS has been used for ambient measurements in Kent, Ohio, for several weeks throughout three seasons. The measured NH3 mixing ratios were usually at the sub-ppbv level and higher in spring (200±120 pptv) than in winter (60±75 pptv) and fall (150±80 pptv). High emissions of SO2 from power plants in this region, and thus possible high acidity of aerosol particles, may explain these low NH3 mixing ratios in general.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atmospheric amines and ammonia measured with a chemical ionization mass spectrometer (CIMS)

We report measurements of ambient amines and ammonia with a fast response chemical ionization mass spectrometer (CIMS) in a southeastern US forest and a moderately polluted midwestern site during the summer. At the forest site, mostly C3-amines (from pptv to tens of pptv) and ammonia (up to 2 ppbv) were detected, and they both showed temperature dependencies. Aerosol-phase amines measured therm...

متن کامل

Ambient pressure proton transfer mass spectrometry: detection of amines and ammonia.

An instrument to detect gaseous amines and ammonia is described, and representative data from an urban site and a laboratory setting are presented. The instrument, an Ambient pressure Proton transfer Mass Spectrometer (AmPMS), consists of a chemical ionization and drift region at atmospheric pressure coupled to a standard quadrupole mass spectrometer. Calibrations show that AmPMS sensitivity is...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Investigation of the unusual behavior of metolachlor under chemical ionization in a hybrid 3D ion trap mass spectrometer.

This article describes the strange behavior of the widely used herbicide metolachlor under chemical ionization conditions in a hybrid source ion trap mass spectrometer in gas chromatography/mass spectrometry (GC/MS) coupling. With the use of ammonia as the reagent gas, metolachlor provides a chlorinated ion at m/z 295/297, almost as abundant as the protonated molecule at m/z 284/286, which cann...

متن کامل

Non-proximate detection of explosives and chemical warfare agent simulants by desorption electrospray ionization mass spectrometry.

Desorption electrospray ionization (DESI) mass spectrometry is used for the selective and sensitive detection of trace amounts of explosives and chemical warfare agent simulants from ambient surfaces at distances of up to 3 meters from the mass spectrometer.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010