Non-invasive detection and assessment of coronary artery disease with multidetector-row computed tomography.
نویسندگان
چکیده
The fast volume coverage of retrospective ECG-gated multidetector-row helical CT(MDCT)arrows for acquisition of the entire heart volume with nearly isotropic spatial resolution(0.5×0.5×0.6 mm)within a single breath-hold. The sub-millimeter spatial resolution enables depiction of the major and also of peripheral coronary artery segments with lumen diameter down to 1 mm. The results of studies of stenosis detection have shown that coronary CT angiography can reliably detect and exclude high-grade stenosis>50%. In addition, preliminary data indicate that MDCT angiography might arrow detection and evaluation of atherosclerotic plaques in different stages. The differentiation of lipid-rich, fibrous and calcified plaques using coronary CT angiography correlates well with the intracoronary ultrasound results based on measurement of the mean HU-value in the lesion. Non-invasive follow-up after
منابع مشابه
[Non-invasive coronary angiography with 16 multidetector-row spiral computed tomography: a comparative study with invasive coronary angiography].
INTRODUCTION AND OBJECTIVES Non-invasive coronary artery angiography by 16 multidetector-row spiral computed tomography is a novel diagnostic tool whose reliability is still unclear. The aim of our study was to compare this technique with invasive coronary angiography. PATIENTS AND METHOD A total of 31 selected patients were examined with both angiographic methods. Non-invasive studies were p...
متن کاملDiagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease.
AIMS Multidetector computed tomography coronary angiography (CTA) has emerged as a feasible imaging modality for non-invasive assessment of coronary artery disease (CAD). Recently, 320-row CTA systems were introduced, with 16 cm anatomical coverage, allowing image acquisition of the entire heart within a single heart beat. The aim of the present study was to assess the diagnostic accuracy of 32...
متن کاملNon-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.
AIMS A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND RESULTS A total of 102 patients underwent both conventional and MDCT coronar...
متن کامل256- and 320-row coronary CTA: is more better?
This editorial refers to ‘The diagnostic accuracy of 256row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease’, by S.-P. Chao et al., on page 1916 and ‘Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the noninvasive evaluation of significant coronary artery disease’, by F.R. de...
متن کاملShaping an ectatic coronary artery: Stentys implantation.
assessment of a first reported case of duplicate right coronary artery. Int J Cardiol 2005;101:329–31. [6] Sawaya FJ, Sawaya JI, Angelini P. Split right coronary artery. Its definition and its territory. Tex Heart Inst J 2008;35:477–9. [7] Yoon SR, Jung AY, Choi SH, Bang OY, Lee NH. Anomalous double right coronary arteries: characteristic multidetector-row computed tomography findings. J Comput...