Accuracy of a method using short inhalation of (15)O-O(2) for measuring cerebral oxygen extraction fraction with PET in healthy humans.
نویسندگان
چکیده
UNLABELLED PET with short inhalation of (15)O-O(2) provides regional oxygen extraction fraction (OEF) in a shorter acquisition time and with less radiation exposure than does the steady-state method. The purpose of this study was to test the accuracy of the short-inhalation technique for estimating OEF in healthy human volunteers. METHODS The final study population included 16 healthy volunteers, who underwent a series of dynamic PET scans consisting of short inhalation of (15)O-CO, short inhalation of (15)O-O(2), and a bolus infusion of (15)O-H(2)O to generate parametric images for cerebral blood volume (CBV), cerebral blood flow (CBF), OEF, and metabolic rate of oxygen (CMRO(2)). About 45 min before PET emission scanning, arterial and jugular blood was sampled through a catheter inserted in a radial artery and the right jugular bulb, respectively. PET-derived OEF (OEFpet) of the whole brain was compared with OEF calculated from the arteriovenous blood-sampling technique (OEFav). RESULTS Whole-brain-averaged CBF (mean +/- SD) measured with PET was 0.40 +/- 0.06 (range, 0.30-0.55) mL/g/min, CBV was 0.05 +/- 0.01 (range, 0.04-0.09) mL/g, CMRO(2) was 2.85 +/- 0.39 (range, 2.35-3.84) mL/100 g/min, and OEFpet was 0.39 +/- 0.06 (range, 0.30-0.51). OEFpet showed a slightly higher value than did OEFav (0.36 +/- 0.05 [range, 0.29-0.46]), but the difference was not significant. The difference in the 2 measurements (OEFpet - OEFav) did not correlate with CBF (r = -0.16; P = not statistically significant [NS]), CBV (r = -0.20; P = NS), CMRO(2) (r = -0.16; P = NS), partial arterial oxygen pressure (r = 0.29; P = NS) or partial arterial carbon dioxide pressure (r = -0.17; P = NS). CONCLUSION Compared with the arteriovenous blood-sampling technique, a technique using short inhalation of (15)O-O(2) did not significantly over- or underestimate global OEF in healthy human volunteers. The PET technique reasonably estimated the cerebral OEF in local brain tissues of healthy human volunteers.
منابع مشابه
PET Quantification of Cerebral Oxygen Metabolism in Small Animals
Understanding cerebral oxygen metabolism is of great importance in both clinical diagnosis and animal experiments because oxygen is a fundamental source of brain energy and supports brain functional activities. Since small animals such as rats are widely used to study various diseases including cerebral ischemia, cerebrovascular diseases, and neurodegenerative diseases, the development of a non...
متن کاملQuantification of cerebral blood flow and oxygen metabolism with 3-dimensional PET and 15O: validation by comparison with 2-dimensional PET.
UNLABELLED Quantitative PET with (15)O provides absolute values for cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO(2)), and oxygen extraction fraction (OEF), which are used for assessment of brain pathophysiology. Absolute quantification relies on physically accurate measurement, which, thus far, has been achieved by 2-dimensional PET (2D PET), t...
متن کاملShorter examination method for the diagnosis of misery perfusion with count-based oxygen extraction fraction elevation in 15O-Gas PET.
UNLABELLED (15)O-Gas PET is useful for evaluating hemodynamic status in patients with ischemic cerebrovascular disease. To reduce examination time and exposure to radioactive gas, we assessed a count-based method with shorter continuous (15)O(2) gas inhalation. METHODS Twenty-five patients (66 +/- 13 [mean +/- SD] y old) with unilateral cerebrovascular stenoocclusive disease were examined by ...
متن کاملRapid quantitative CBF and CMRO2 measurements from a single PET scan with sequential administration of dual 15O-labeled tracers
Positron emission tomography (PET) with (15)O tracers provides essential information in patients with cerebral vascular disorders, such as cerebral blood flow (CBF), oxygen extraction fraction (OEF), and metabolic rate of oxygen (CMRO(2)). However, most of techniques require an additional C(15)O scan for compensating cerebral blood volume (CBV). We aimed to establish a technique to calculate al...
متن کاملArterial fraction of cerebral blood volume in humans measured by positron emission tomography.
In quantitative functional neuroimaging with positron emission tomography (PET) and magnetic resonance imaging (MRI), cerebral blood volume (CBV) and its three components, arterial, capillary, and venous blood volumes are important factors. The arterial fraction for systemic circulation of the whole body has been reported to be 20-30%, but there is no report of this fraction in the brain. In th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 45 5 شماره
صفحات -
تاریخ انتشار 2004