Whole brain single shot diffusion weighted EPI at 7 Tesla using parallel transmit multislice multiband RF pulses
نویسندگان
چکیده
Introduction: Simultaneous Multi-Slice (SMS) imaging [1] using MultiBand (MB) RF pulses has shown great success in functional and diffusion weighted (DW) MRI studies of the brain [2-5]. Recently, this technique has been combined with parallel transmission (pTx) and it has been demonstrated that pTx MB pulse design [6] can significantly improve transmit B1 (B1+) homogeneity at 7T and/or reduce RF power consumption relative to a single channel Circular Polarized (CP) mode application. Those results were obtained for a few slices in the brain using a gradient echo imaging sequence and did not tackle the problem of whole brain coverage or more challenging spin-echo based acquisitions. In the present study, advances towards volumetric coverage with pTx MB pulses is reported and results of whole brain singleshot, diffusion weighted echo planar imaging (DW-EPI) at 7T using pTx MB RF pulses are presented. Methods: Experiments were conducted at 7T equipped with a 16-channel prototype pTx system (Siemens, Erlangen, Germany). A number of healthy volunteers who signed a consent form were scanned and representative results are shown. A head array with 16 azimuthally distributed elements, similar to [7], was employed for both RF transmission and reception. To capitalize on the coil geometry, coronal slices were imaged. For practical scan session times, we employed a new slab-wise pulse design [8] where four contiguous slabs jointly covering the brain volume in coronal views were prescribed to design a single 1-spoke pTx MB4 pulse; the band-specific phase and gain of the four pTx single band (SB) pulses were calculated from B1+ maps [9] estimated only from 11 slices that were equidistantly distributed over the four slabs (Fig. 1). The target was uniform B1+ within brain tissues that were defined from manually drawn regions of interest on the B1+ maps. The RF shim sets for individual pTx SB pulses were obtained via magnitude least squares optimization [10] and based on L-curve criteria. To acquire whole brain single-shot DW-EPI datasets, a new pulse sequence utilizing pTx MB pulses was developed based on the SMS/MB imaging sequence that is currently being used in the WashU consortium of the Human Connectome Project (HCP, http://humanconnectome.org). The same RF shim set was utilized for both excitation and refocusing. The DW images were further analyzed to derive diffusion tensor images (DTI) following the HCP data processing pipeline [11]. For comparison, a 3D B1 phase shimming targeting a CP-like mode B1+ distribution [12] was also performed to mimic single channel transmission and was used to assemble so called “CP mode MB pulses” for data acquisition. For all acquisitions, RF voltages were adjusted to achieve the nominal flip angles (i.e., 90 for excitation and 180 for refocusing) at the maximum flip angle across the whole brain. All pulse calculations were performed in Matlab (Mathworks, USA). Results and Discussion: Using pTx MB pulses gave rise to drastically improved B1+ homogeneity across the brain as compared to the CP mode counterpart. The std/mean of B1+ variations decreased from ~27% for CP mode to ~12% for pTx, concurrently with a ~40% reduction in total RF power. Correspondingly, the traditional image signal dropout seen in the lower brain when using CP mode MB pulses to acquire DW images was effectively recovered by using the pTx MB pulses (Fig. 2). As a result, significantly enhanced depiction of the fiber orientation was achieved with pTx MB, especially in the cerebellum and midbrain regions. Additionally, calculations of RF power deposition in tissues (i.e. SAR) based on electromagnetic modeling revealed that although not explicitly constrained in pulse design, peak 10g SAR was reduced by 21% when using pTx MB pulses. This was mostly due to the fact that each pTx SB pulse tends to deliver the majority of its RF power (>70%) via the coil elements that are near the target slices, yielding localized and non-overlapping SAR hot spots between different bands. As a result, these SB hot spots do not add up during the application of the summed MB pulse, thereby leading to a reduced local SAR. In conclusion, we have successfully demonstrated the utility of pTx technology for SMS/MB imaging when pursuing whole brain DW-EPI at 7T. Critical to this accomplishment is an efficient and practical slab-wise pTx MB RF pulse design which bases the pulse calculation on a few contiguous slabs covering the entire volume of interest rather than on the many individual imaging slices to be obtained in the data acquisition. Future work includes the investigation of the potential benefit of designing multiple slab-wise pTx MB pulses and using a Z-stacked RF array for whole brain pTx SMS/MB imaging. References: [1]. Larkman DJ, et al. (2001) JMRI 13: 313-317. [2]. Moeller S, et al. (2010) MRM 63: 1144-1153. [3]. Feinberg DA, et al. (2010) PLoS ONE 5: e15710. [4]. Smith SM, et al. (2012) PNAS 109: 3131-3136. [5]. Setsompop K, et al. (2012) MRM 67: 1210-1224. [6]. Wu X, et al. (2013) MRM 70: 630–638. [7]. Adriany et al. (2008) MRM 59:590-97. [8]. Wu X, et al. submitted to ISMRM 2014. [9]. Van de Moortele PF, et al. ISMRM 2007 p. 1676. [10]. Setsompop K, et al. (2008) MRM 59: 908-915. [11]. Sotiropoulos SN, et al. (2013) NeuroImage 80: 125-143. [12]. Schmitter S, et al. ISMRM 2012 p. 3472. Acknowledgments: The authors would like to thank Dr. Jinfeng Tian for running the electromagnetic modeling of the RF array used in this study. This work was supported by NIH grants including P41 EB015894, S10 RR026783, R21 EB009133, R01 EB006835 and R01 EB007327.
منابع مشابه
Scan time reduction for readout‐segmented EPI using simultaneous multislice acceleration: Diffusion‐weighted imaging at 3 and 7 Tesla
PURPOSE Readout-segmented echo-planar imaging (rs-EPI) can provide high quality diffusion data because it is less prone to distortion and blurring artifacts than single-shot echo-planar imaging (ss-EPI), particularly at higher resolution and higher field. Readout segmentation allows shorter echo-spacing and echo train duration, resulting in reduced image distortion and blurring, respectively, i...
متن کاملMultiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging
Echo planar imaging (EPI) is an MRI technique of particular value to neuroscience, with its use for virtually all functional MRI (fMRI) and diffusion imaging of fiber connections in the human brain. EPI generates a single 2D image in a fraction of a second; however, it requires 2-3 seconds to acquire multi-slice whole brain coverage for fMRI and even longer for diffusion imaging. Here we report...
متن کاملZoomed EPI-DWI of the Pancreas Using Two-Dimensional Spatially-Selective Radiofrequency Excitation Pulses
BACKGROUND Implementation of DWI in the abdomen is challenging due to artifacts, particularly those arising from differences in tissue susceptibility. Two-dimensional, spatially-selective radiofrequency (RF) excitation pulses for single-shot echo-planar imaging (EPI) combined with a reduction in the FOV in the phase-encoding direction (i.e. zooming) leads to a decreased number of k-space acquis...
متن کاملUltrahigh field single-refocused diffusion weighted imaging using a matched-phase adiabatic spin echo (MASE).
PURPOSE To improve ultrahigh field diffusion-weighted imaging (DWI) in the presence of inhomogeneous transmit B1 field by designing a novel semi-adiabatic single-refocused DWI technique. METHODS A 180° slice-selective, adiabatic radiofrequency (RF) pulse of 4 ms duration was designed using the adiabatic Shinnar-Le Roux algorithm. A matched-phase slice-selective 90° RF pulse of 8 ms duration w...
متن کاملAdvanced Diffusion Acquisition
Target Audience: Methodologically oriented scientists interested in accelerating the acquisition of diffusionweighted data using multiband/simultaneous multi-slice techniques. Outcome/Objectives: The presentation will explain how to acquire and reconstruct multiband images with diffusion weighting. The audience should understand the additional constraints imposed by performing diffusion-weighti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013