The Raji cell radioimmune assay for detecting immune complexes in human sera.

نویسندگان

  • A N Theofilopoulos
  • C B Wilson
  • F J Dixon
چکیده

A sensitivie and simple procedure for the detection and quantitation of soluble complement (C)- fixing immune complexes in sera of patients with various disease states has been developed by utilizing C receptors on Raji cells. These cells lack membrane-bound immunoglobulin but have receptors for IgG Fc, C3b, C3d, and possibly with other C proteins. Uptake experiments showed that both aggregated human gamma globulin (AHG) and 7S IgG bound to receptors for IgG Fc; however, AHG reacted with C bound to cells only via receptors for C and this binding was much more efficient than via IgG Fc receptors. AHG was used as an in vitro model of human immune complexes and its uptake by Raji cells was quantitated by 125I-radiolabeled antihuman IgG. The limit of sensitivity of this test was 6 mug AHG/ml serum. The ability of Raji cells to detect AHG in serum depended on the amount of radioactive antibody used and the size of aggregates. The presence of an excess of C somewhat inhibited binding of AHG containing C to Raji cells. The efficient binding of AHG by receptors for C on Raji cells was used for the detection and quantitation of immune complexes in human sera. Raji cells were incubated with sera to be tested and then reacted with excess radiolabeled antihuman IgG; the amount of radioactivity bound to the washed cells was determined and referred to a standard curve of radioactive antibody uptake by cells previously incubated with increasing amounts of AHG in serum. Thereby immune complexes were detected and quantitated in serum hepatitis, systemic lupus erythematosus, vasculitis, subacute sclerosing panencephalitis, dengue hemorrhagic fever, and malignancies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Nature of Immune Complexes in Human Cancer Sera 1

Sera from 517 patients with various types of malignancies were assayed for immune complexes (ICs) by the Raji cell radioimmune assay. The incidence of immune complexes in these patients ranged from 16 to 52% as compared to 19% in normal controls. Increases in tumor mass and metastatic disease were associated with high levels of circulating ICs. Immunization of melanoma patients with BCG and tum...

متن کامل

Application of the solid phase C1q and Raji cell radioimmune assays for the detection of circulating immune complexes in glomerulonephritis.

The C1q solid phase and Raji cell radioimmune assays were used to determine the frequency of detectable circulating immune complexes in patients with glomerulonephritis. In this study, 46% of 56 patients with glomerulonephritis had evidence of circulating immune complexes. More important, circulating immune complexes were associated with some, but not other, types of glomerulonephritis. Thus, i...

متن کامل

Evidence for Detection of Raji-directed Immunoglobulin G Antibody in Sera from Patients with Systemic Lupus Erythematosus

at 37°C of IgG from the sera of 16 patients with systemic lupus erythematosus (SLE) to pronasedigested Raji cells was reduced much less consistently and extensively (9-100% reduction; mean reduction of 51%). In more detailed studies of two SLE sera, sucrose density gradient centrifugation showed that >50% of the IgG binding to undigested Raji cells sedimented in the 7S region. Pepsin digestion ...

متن کامل

Circulating immune complexes in Lyme arthritis. Detection by the 125I-C1q binding, C1q solid phase, and Raji cell assays.

We have found immunoglobulin (Ig) G-containing material consistent with immune complexes in the sera of patients with Lyme arthritis. It was detected in 29 of 55 sera (55%) from 31 patients by at least one of three assays: (125)I-C1q binding, C1q solid phase, or Raji cell. The presence of reactive material correlated with clinical aspects of disease activity; it was found early in the illness, ...

متن کامل

Evaluation of a Cordia-IC enzyme-linked immunosorbent assay kit for the detection of circulating immune complexes.

A commercial kit (Cordia-IC) from Cordis Laboratory, Miami, Fla., was compared with the Raji cell radioimmunoassay for its ability to detect circulating immune complexes (CIC) in sera from 30 control subjects and 118 patients with infectious diseases. The 118 patients were categorized into the following groups: (i) 23 patients with bacterial endocarditis, (ii) 41 patients with bacteremia from a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 57 1  شماره 

صفحات  -

تاریخ انتشار 1976