The Development of Biodegradable Metallic Screws and Suture Anchors for Soft Tissue Fixation in Orthopaedic Surgery

نویسندگان

  • Kwang Eun Kim
  • Patrick J. McMahon
چکیده

Surgical treatment for injuries to soft connective tissues are estimated at about 800,000 cases each year in the US. For these surgical procedures, interference screws or suture anchors are needed. Currently, materials used for the devices are non-degradable metals or bioresorbable polymers. However, these materials do lead to complications. Metallic materials suffer from difficulties encountered during revision surgery and interference with magnetic resonance imaging; whereas, polymeric materials lead to device fracture during implantation, inconsistent degradation rates, and poor osteointegration. The overall goal of this dissertation was to explore the use of Mg-based materials as an alternative to the existing materials. Specifically, the studies focused on Mg-based interference screws for ACL reconstruction and suture anchors for rotator cuff repair. First, a Mg-based interference screw was designed and optimized through in-vitro testing and finite element analysis (FEA). At time zero, ACL reconstruction with Mg-based interference screws was found to restore initial joint stability as well as the in-situ load in the ACL close to the levels of the intact. Also, structural properties of the femur-graft-tibia complex (FGTC) with a Mg-based interference screw were comparable as those with a titanium control. In a follow-up study, joint stability and graft function after 12 weeks of healing were found to be comparable to past studies of ACL reconstruction in a goat model using the robotic/UFS testing system. The stiffness and iv ultimate load of the FGTC at 12 weeks were comparable to those at time zero. These results indicate that Mg-based interference screws allow for proper healing of the graft. Similarly, a Mg-based suture anchor was also designed and developed. Using FEA, the thread depth and pitch of the anchor could be optimized. It was then demonstrated that Mg-based suture anchors could achieve superior fixation over commercially available polymer suture anchors as it could provide a higher stiffness and ultimate load. In summary, the potential of Mg-based alloys for fixation of soft tissues to bone has been clearly demonstrated. We hope that the current findings would help the development of a novel class of biodegradable metallic implants that would ultimately help patients with improved outcomes. Table 2. Anterior-posterior tibial translation (APTT) of intact, ACL-deficient, and reconstructed stifle joints and in situ forces in the ACL and replacement graft in response to a 67 N anterior-posterior tibial load at time zero.. Table 3. Residual elongation after the 1st, 2nd, and 3rd cyclic loading test and structural …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fixation of Soft Tissue to Bone: Techniques and Fundamentals.

A myriad of orthopaedic injuries require surgical fixation of torn connective tissue to an osseous insertion site with either direct repair or reconstruction with a soft-tissue graft. Numerous factors influence the strength of a soft-tissue-to-bone fixation construct, including tissue quality, implant strength, contact area and pressure, and tensioning. Each fixation technique differs with resp...

متن کامل

The Outcomes of Pilon Fracture Treatment: Primary Open Reduction and Internal Fixation Versus Twostage Approach

Background: Pilon fracture is one of the challenging injuries in orthopedic surgery. Associated soft tissue injury is animportant factor in choosing treatment options. Two major methods of treatment are considered as one-stage openreduction internal fixation (ORIF) and two-stage treatment (primary external fixation and secondary ORIF). The latter ismost accepted in literature. In the current st...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Interference screw fixation of tendontransfers in the foot and ankle.

Tendon transfers pptay an important role in reconstructive foot and ankle surgery. Multiple methods for fixation of tendon to bone are used including suture of tendon to periosteum, suture into bone troughs, suture anchors, and passage through bone tunnels. With the increasing populatity of hamstring tendon anterior cruciate ligament reconstructions has come new fixation technology. Soft-tissue...

متن کامل

Arthroscopic Posterior Glenoid Fracture Fixation Using Knotless Suture Anchors

Shoulder instability after a posterior glenoid rim fracture is rare and potentially difficult pathology to treat. Operative techniques often involve a large dissection to view the fragments resulting in local soft tissue injury. Internal fixation is often achieved with interfragmentary screws; however, this may not be possible with small or multifragmentary fracture patterns. We describe an art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014