Two Versus Three Narrow-Diameter Implants with Locator Attachments Supporting Mandibular Overdentures: A Two-Year Prospective Study

نویسندگان

  • Ali M. El-Sheikh
  • Omar F. Shihabuddin
  • Sahar M. F. Ghoraba
چکیده

Purpose. To compare treatment outcome (survival rate, condition of hard and soft peri-implant tissues) and prosthodontic maintenance requirements of two versus three narrow-diameter bone level implants with Locator attachments supporting mandibular overdentures. Materials and Methods. Twenty completely edentulous patients with atrophic mandibles were treated. Ten patients (Group A) were treated with overdentures supported by two narrow (3.3-mm diameter) implants (Straumann AG, Basel, Switzerland) and ten patients (Group B) were treated with overdentures supported by three narrow implants. Locator (Zest Anchors, USA) attachments were used for prosthetic anchorage. Standardized clinical and radiographic parameters (survival rate, plaque index, calculus index, gingival index, bleeding index, probing depth and marginal bone loss) were evaluated at the time of the completion of the prosthetic treatment (baseline) and after 6, 12 and 24 months of functional loading. Prosthodontic maintenance requirements were also scored. Results. Only one implant was lost (Group B) during the healing period. There were no significant differences with regards to any of the studied clinical and radiographic parameters between the two groups (P > 0.05). Few prosthetic complications were recorded. Conclusions. No need to insert more than two narrow-diameter bone level implants with Locator attachments in cases of atrophic mandible to support an overdenture, however, long-term prospective studies are required to support this notion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maxillary Three-Implant Overdentures Opposing Mandibular Two-Implant Overdentures: 10-Year Prosthodontic Outcomes.

PURPOSE This study aimed to evaluate the 10-year prosthodontic outcomes with splinted and unsplinted designs for maxillary overdentures on three implants opposing mandibular two-implant overdentures. MATERIALS AND METHODS Using two similar implant systems, 40 edentulous participants with existing mandibular two-implant overdentures were randomly allocated to two prosthodontic treatment groups...

متن کامل

Influence of Number of Implants and Attachment Type on Stress Distribution in Mandibular Implant-Retained Overdentures: Finite Element Analysis

AIM This study aimed to compare the stresses generated by using two or four root form dental implants supporting mandibular overdentures that were retained with ball and locator attachments. METHODS Under ANSYS environment, four 3D finite element models were prepared. These models simulated complete overdentures supported by two or four implants with either ball or locator attachments as a co...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures

This study aimed to investigate the effect of attachment type on the load transmitted to implants and the residual ridge in a mandibular two-implant-supported overdenture in a model study. Ball attachments, locator attachments, and round-bar attachments were selected and examined. Static and dynamic vertical loads of 100 N were applied in the right first molar region. The load on the implants w...

متن کامل

Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

PURPOSE The aim of the present study was to evaluate, by means of strain gauge analysis, the effect of different implant angulations on strains around two implants retaining mandibular overdenture with Locator attachments. MATERIALS AND METHODS Four duplicate mandibular acrylic models were constructed. Two implants were inserted in the canine regions using the following degrees of distal incl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012