A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.

نویسندگان

  • Helmut Hager
  • Goutham Mandadi
  • Debra Pulley
  • J Chris Eagon
  • Edward Mascha
  • Benjamin Nutter
  • Andrea Kurz
چکیده

BACKGROUND In morbidly obese patients, oscillometric blood pressure measurements with an upper-arm cuff are often difficult to perform. The alternative method, invasive blood pressure monitoring, can be difficult to place and is associated with risks. A wrist-mounted blood pressure-monitoring device, the Vasotrac, provides accurate blood pressure measurements in lean patients. Even in the obese, wrist morphology remains relatively unchanged. We thus assessed the degree to which blood pressure measurements with the Vasotrac on the wrist and cuff measurements agree with invasive arterial blood pressure monitoring. METHODS We evaluated 22 morbidly obese patients undergoing bariatric surgery lasting 3.8+/-1.1 h. Intraoperative blood pressure was simultaneously measured using the Vasotrac mounted on one wrist; an arterial catheter was inserted in the opposite radial artery, and an oscillometric cuff was positioned on the upper arm. Preoperative patient comfort was evaluated on a scale from 1 to 10, with 10 being most uncomfortable, just after the first oscillometric cuff inflation. Values from the Vasotrac and arterial catheter were recorded at 5-s intervals. Bias, precision, and clinically acceptable agreement were calculated between the two continuous monitoring devices and between the arterial catheter and the cuff measurements, with the arterial catheter providing the reference value. RESULTS The patients' age was 44.3+/-9.5 years (mean+/-SD), body mass index was 66.7+/-13.8 kg/m2, and arm circumference was 48.6+/-7.5 cm. Patients found the Vasotrac more comfortable than the oscillometric device [1.7+/-1.8 vs 5.3+/-0.5 (P=0.009)]. A total of 40,411 pairs of values from the Vasotrac and arterial catheter were recorded. Lin's concordance correlation coefficient (95% CI) for mean arterial blood pressure measured between the arterial line and the Vasotrac was 0.74 (0.67, 0.82). The bias (mean error) was -0.25 mmHg; however, the Bland-Altman limits where 95% of individual pressure differences are expected to fall was (-20, 20) mmHg. The precisions for diastolic and systolic pressures were even worse. CONCLUSION The Vasotrac was more comfortable than an oscillometric device. Although the average accuracy was good, individual mean Vasotrac and noninvasive blood pressure pressures often differed considerably from arterial values. These results suggest that the Vasotrac monitor should not be substituted for an arterial catheter in super-obese patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

تخمین بدون کاف فشارخون مبتنی بر ویژگی‌های زمانی سیگنال نبض

Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...

متن کامل

Comparing Effects of Listening to Nature Sounds and Lavender Inhalation on Hemodynamic Parameters among Patients Undergoing Cataract Surgery with Regional Anesthesia: A Randomized Controlled Trial

Background and purpose: Candidates for cataract surgery have high anxiety and worry for various reasons which may cause changes in their hemodynamic parameters. Maintaining hemodynamic stability during anesthesia and surgery is very important. This study aimed at comparing the effects of listening to nature sounds and lavender inhalation on hemodynamic parameters in patients undergoing cataract...

متن کامل

A comparison of radial artery blood pressure determination between the Vasotrac device and invasive arterial blood pressure monitoring in adolescents undergoing scoliosis surgery.

UNLABELLED The Vasotrac device (Medwave, Arden Hills, MN) allows noninvasive measurement of arterial blood pressure (BP) and arterial waveform. We have previously demonstrated agreement between the Vasotrac and continuous intraarterial BP monitoring in children with a stable circulation after cardiac surgery in the cardiac intensive care unit. To assess this monitor during different physiologic...

متن کامل

The Effect of Gradual Departure accompanied by Activity in Bed on Hemodynamic Parameters of Patients Underwent Sleeve Gastrectomy

Introduction: Several therapeutic methods with different efficacy for dealing with obesity are presented. Different methods for treating obesity have been more successful in the treatment of gastrectomy. Despite the positive effect of this surgery in treating obesity, sleeve gastrectomy causes imbalance of hemodynamic parameters similar to other invasive interventions. Therefore, the aim of thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Obesity surgery

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2009