Effect of Electrical Stimulation on Blood Flow Velocity and Vessel Size
نویسندگان
چکیده
Interferential current electrical stimulation alters blood flow velocity and vessel size. We aimed to investigate the changes in the autonomic nervous system depending on electrical stimulation parameters. Forty-five healthy adult male and female subjects were studied. Bipolar adhesive pad electrodes were used to stimulate the autonomic nervous system at the thoracic vertebrae 1-4 levels for 20 min. Using Doppler ultrasonography, blood flow was measured to determine velocity and vessel size before, immediately after, and 30 min after electrical stimulation. Changes in blood flow velocity were significantly different immediately and 30 min after stimulation. The interaction between intervention periods and groups was significantly different between the exercise and pain stimulation groups immediately after stimulation (p<0.05). The vessel size was significantly different before and 30 min after stimulation (p<0.05). Imbalances in the sympathetic nervous system, which regulates balance throughout the body, may present with various symptoms. Therefore, in the clinical practice, the parameters of electrical stimulation should be selectively applied in accordance with various conditions and changes in form.
منابع مشابه
MECHANISMS OF BLOOD FLOW INCREASE INDUCED BY ELECTRICAL STIMULATION
Previous studies have shown that electrical stimulation (ES) increases blood flow, but the exact mechanisms are not clear. The present study was designed to clarify some of the underlying mechanisms involved in this phenomenon. White adult rabbits Lt.-6 months old were used. Animals were anesthetized by sodium pentobarbital (40 mg/kg, IV) and skin blood flow in the thoracic back was recorde...
متن کاملTHE EFFECT OF CARRAGEENAN-INDUCED INFLAMMATION ON BLOOD FLOW IN THE RABBIT KNEE JOINT
Experiments were carried out on anesthetized adult New Zealand rabbits. Acute joint inflammation was achieved by intra-articular injection of 2% carrageenan. Radiolabelled microspheres were used to measure the effect of acute inflammation on blood flow in the knee joint and establish whether neural influences on blood vessel caliber were affected. Surgical exposure of the posterior joint "capsu...
متن کاملStudy of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction
Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...
متن کاملComputational simulations of nanoparticle transport in a three-dimensional capillary network
Objective(s): Multifunctional nanomedicine is the new generation of medicine, which is remarkably promising and associated with the minimum toxicity of targeted therapy. Distribution and transport of nanoparticles (NPs) in the blood flow are essential to the evaluation of delivery efficacy. Materials and Methods: In the present study, we initially designed a phantom based on Murray’s mini...
متن کاملA Numerical Analysis for the Effect of Slip Velocity and Stenosis Shape on Non-Newtonian Flow of Blood (TECHNICAL NOTE)
The aim of this paper is to study the effect of slip velocity and shape of stenosis on non-Newtonian flow of blood through a stenosed arterial segment. Blood is modeled as Bingham-Plastic fluid in a uniform circular tube with a radially non-symmetric stenosis. The problem is investigated by a joint effort of analytical and numerical techniques. The influence of stenosis shape parameter, slip ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017