Loss of Guide Wire: A Lesson Learnt Review of Literature

نویسندگان

  • Rajiv Srivastav
  • Vishal Yadav
  • Dimpy Sharma
  • Vikas Yadav
چکیده

Catheterization of central veins is a routine technique which is widely used in emergency department and medical intensive care units. Seldinger's technique is widely used to place central venous and arterial catheters and is generally considered safe. The technique does have multiple potential risks. Guide wire-related complications are rare but potentially serious. We describe a case of a lost guide wire during central venous catheter (CVC) insertion followed by a review of the literature of this topic. Measures which can be taken to prevent such complications are explained in detail as well as recommended steps to remedy errors should they occur.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guide Wire Loss of Femoral Venous Cannulation: Case Report and Literature Review.

Placement of a central venous catheter (CVC) is a common procedure, often replaced by femoral vein cannulation. The overall complication rate is 12 - 15%. Loss of a complete guide wire into the circulation is a rare and preventable complication. Here we report a case of guide wire loss during femoral venous cannulation and literature review.

متن کامل

Research Productivity and Economic Growth: A Policy Lesson Learnt from Across the Globe

The relationship between research productivity and economic growth is the subject of information science which deals in this study to examine the impact of number of publications, research & development (R&D) expenditures and researchers involved in R&D activities on economic growth in the World’s largest regions for the period of 1980–2011. The study further expanded the research-growth nexus ...

متن کامل

Adolescence spinal epidural abscess with neurological symptoms: case report, a lesson to be re-learnt

  Epidural abscess of the spinal column is a rare condition that can be fatal if left untreated. It promptly progresses and can cause neurologic paralysis, urinary retention or cauda equina syndrome. Compromised immune system that occurs in patients with diabetes mellitus, AIDS, chronic renal failure, alcoholism, or cancer is a predisposing factor. It mostly occurs in adults. Here we would like...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013