Evaluation of the Accuracy of Two Marking Methods and the Novel toriCAM Application for Toric Intraocular Lens Alignment.

نویسندگان

  • Andreas Pallas
  • Tun Kuan Yeo
  • Michelle Trevenen
  • Graham Barrett
چکیده

PURPOSE To compare the accuracy of two common reference marking methods for toric intraocular lens alignment before and after using the novel toriCAM application. METHODS In this prospective, randomized study, 22 participants were randomly allocated to two groups, either freehand or slit-lamp-assisted marking. Corneal markings at 0° and 180° were made using either method. The toriCAM application on a smartphone was then used to assess the rotational alignment of these markings and compared to the actual alignment as measured by the Zaldivar calipers on the iTrace Topographer (Tracey Technologies, Houston, TX) as a reference. The errors in marking with and without using the application were analyzed for all patients in each cohort and determined for each marking method. RESULTS Twenty eyes of 11 patients were marked using the freehand method and 20 eyes of the other 11 patients were marked using the slit-lamp method. The mean absolute error of all markings before toriCAM adjustment was 3.18° ± 2.22°. This was significantly reduced to 1.28° ± 1.34° after using the application (P < .001). This improvement was also noted separately in the freehand and slit-lamp groups. Comparison of the freehand and slit-lamp methods did not show any statistically significant difference in accuracy at both time points. CONCLUSIONS The novel toriCAM application is able to significantly improve the accuracy of reference marking for both freehand and slit-lamp methods. [J Refract Surg. 2018;34(3):150-155.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison Between Digital and Manual Marking for Toric Intraocular Lenses

To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX)...

متن کامل

Surgical management of astigmatism with toric intraocular lenses.

Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs) compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for ch...

متن کامل

Sunalp YAG Laser Lens, A Novel Method for Marking the Axis of Astigmatism Before Cataract Surgery and Toric Lens Implantation

Purpose: Comparison of astigmatic correction and visual acuity outcomes in patients implanted with toric intraocular lenses following cataract surgery reference marked pre-operatively manually with a pen or with YAG laser, in conjunction with the Sunalp YAG Laser Lens. Methods: 16 eyes from 16 patients were divided into two groups of 8 patients each. Pre-operativelly, the eye of one group was r...

متن کامل

Monte Carlo simulation of expected outcomes with the AcrySof® toric intraocular lens

BACKGROUND To use a Monte Carlo simulation to predict postoperative results with the AcrySof Toric lens, evaluating the likelihood of over- or under-correction using various toric lens selection criteria. METHODS Keratometric data were obtained from a large patient population with preoperative corneal astigmatism <= 2.50D (2,000 eyes). The probability distributions for toric marking accuracy,...

متن کامل

Evaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.

PURPOSE To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). METHODS A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 2018