Two-line atomic fluorescence flame thermometry using diode lasers

نویسندگان

  • J. Hult
  • I. S. Burns
  • C. F. Kaminski
چکیده

This paper reports on the first application of diode laser based LIF for pointwise temperature measurements in flames. The technique is based on two-line atomic fluorescence (TLAF) thermometry of indium atoms seeded at trace levels into the flame. Two novel extended cavity diode laser systems (ECDLs) were developed, providing tunable single-mode radiation around 410 and 451 nm, respectively, to excite the temperature sensitive 5P1/2–6S1/2 and 5P3/2–6S1/2 transitions of indium. The wide tuning range of the ECDLs allowed scans over the entire pressure broadened hyperfine structure of both transitions to be performed with signal-to-noise ratios exceeding 50 on single wavelength sweeps (at 20 Hz). We present a modified TLAF detection scheme that requires only a single detector and obviates the need for detection system calibration. Spatially resolved temperature profiles were obtained from a laminar premixed CH4/air flame and found to be in excellent agreement with temperatures obtained from high-resolution OH LIF scans. The accuracy and spatial resolution of the technique makes this an attractive alternative to traditional, more complex, and expensive, temperature measurement techniques of similar or better precision. Finally, we demonstrate that PLIF imaging of atom distributions in flames is possible using low power diode lasers. 2004 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-repetition-rate combustion thermometry with two-line atomic fluorescence excited by diode lasers.

We report on kilohertz-repetition-rate flame temperature measurements performed using blue diode lasers. Two-line atomic fluorescence was performed by using diode lasers emitting at around 410 and 451 nm to probe seeded atomic indium. At a repetition rate of 3.5 kHz our technique offers a precision of 1.5% at 2000 K in laminar methane/air flames. The spatial resolution is better than 150 microm...

متن کامل

A thermometry technique based on atomic lineshapes using diode laser LIF in flames

We report on the development of a novel diode laser thermometry technique permitting temperature measurements in flames based on the fluorescence lineshapes of an atomic tracer species. The technique, which we term OLAF (one-line atomic fluorescence) requires only a single diode laser source for excitation, is simple to implement, and has excellent spatial resolution. Temperatures are deduced f...

متن کامل

Diode laser atomic fluorescence temperature measurements in low-pressure flames

Temperature measurements have been performed in a low-pressure flame by the technique of diode laser induced atomic fluorescence. The experiments were done in a near-stoichiometric flat-flame of premixed methane, oxygen and nitrogen, at a pressure of 5.3 kPa. Indium atoms were seeded to the flame and probed using blue diode lasers; the lineshapes of the resulting fluorescence spectra were used ...

متن کامل

Two-Line Atomic Fluorescence for Thermometry in Reactive Flows

Advances in the field of laser-based combustion diagnostics over the past decades have allowed for detailed characterisation, modelling and increased understanding of the complex combustion process. However; many combustion phenomena are still unexplained and there is a continued need for development and application of diagnostic tools to further the understanding of the combustion process. One...

متن کامل

A method for performing high accuracy temperature measurements in low-pressure sooting flames using two-line atomic fluorescence

We demonstrate a step change in the capability of diode laser excited two-line atomic fluorescence (TLAF) thermometry and show it is well-suited to the study of low-pressure sooting flames. The new developments to the technique reported here were essential to achieve the accuracy (±41 K) and precision (±8 K) required for useful measurements in such systems. This represents the first application...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004