Fluid Chamber Membrane
نویسندگان
چکیده
A new format for solid-phase immunoassays has been developed in which a monoclonal antibody-coated membrane, incorporated into a cylindrical, disposable device, regulates sample and reagent delivery. We illustrate the method with a two-site, immunoenzymometnc assay that can detect human choriogonadotropin at less than 50 mt. units/L (4 pg/L) in urine and less than 25 mt. units/L (2 j.tg/L) in serum and takes less than 5 mm to perform. The solid-phase antibody is located in a circular area in the center of the membrane so that in the presence of the hormone, after addition of substrate, a blue enzyme product is generated in this circular area. The high ratio of surface area to volume within the microporous matrix of the membrane assures short diffusion distances and therefore rapid binding of liquidphase reagents to the solid phase. Pseudo-first-order reaction kinetics describe the binding of antigen to immobilized antibody and the binding of enzyme-labeled antibody to immobilized antigen. The speed and simplicity of this format may facilitate testing for many analytes, both soluble and particulate, as well as serological testing.
منابع مشابه
The membrane chamber: a new type of in vitro recording chamber.
In vitro brain slice electrophysiology is a powerful and highly successful technique where a thin slice is cut from the brain and kept alive artificially in a recording chamber. The design of this recording chamber is pivotal to the success and the quality of such experiments. Most often one of two types of chambers is used today, the interface chamber or the submerged chamber. These chambers, ...
متن کاملHydroelastic Vibration of a Circular Diaphragm in the Fluid Chamber of a Reciprocating Micro Pump
Reciprocating diaphragm micro-pumps are the most common type among indirectly–driven micro-pumps. They operate by reciprocating the diaphragm with associated check valves. This paper addresses the Hydroelastic vibration of circular elastic diaphragm interacting with the incompressible and inviscid liquid inside the cylindrical chamber with a central discharge opening. Taking into account axisym...
متن کاملExperimental study and application of computational fluid dynamics on the prediction of air velocity and temperature in a ventilated chamber
The shape of the air flow in the interior is heavily influenced by the air distribution system and the way air enters and exits. By numerically simulating flow by computational fluid dynamics, one can determine the flow pattern and temperature distribution and, with the help of the results, provide an optimal design of the air conditioning system. In this study, a chamber was first constructed ...
متن کاملRecurrent Annular Peripheral Choroidal Detachment after Trabeculectomy
We report a challenging case of recurrent flat anterior chamber without hypotony after trabeculectomy in a 54-year-old Black male with a remote history of steroid-treated polymyositis, cataract surgery, and uncontrolled open angle glaucoma. The patient presented with a flat chamber on postoperative day 11, but had a normal fundus exam and intraocular pressure (IOP). Flat chamber persisted despi...
متن کاملAn alternative technique for Descemet’s membrane detachment following phacoemulsification: case report and review of literature
BACKGROUND Descemet's membrane detachment (DMD) is one of the most serious complications of modern cataract surgery. We present an alternative technique for management of DMD with a review of the literature on current strategies for the treatment of DMD. CASE PRESENTATION A 74-year-old woman developed DMD after phacoemulsification and failed the first descemetopexy with air tamponade. An alte...
متن کاملComputational Study of Radiative and Convective Heat Transfer in a Cylindrical Combustion Chamber
In this paper, the effect of cold air on the fluid flow inside the cylindrical combustion chamber and its wall temperature distribution have been studied computationally, taking into account the effect of radiative heat transfer from hot gases. The results have been compared with the case that radiative heat transfer was neglected. It is observed that the reattachment length increases when incr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004