The interaction mechanism between AC and DC systems in a hybrid AC-DC transmission grid is discussed with PSS/E software. Analysis shows that receiving-end AC faults may cause much more damage on the HVDC system operation than the sending-end AC faults in a multi-infeed HVDC system, and the damage severity depends on the power recovering rate of the HVDC systems. For HVDC systems with slow power recovering rate, the receiving-end AC faults may probably be a critical factor to constrain power transfer limits. Larger capacity of HVDC system means not only higher power transfer-limit of the parallel connected AC-DC transmission grid, but also more expensive stabilizing cost.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technology and Development of 800 kV HVDC Applications

Bulk Power HVDC transmission schemes over distances of up to 2000 km are currently under planning for various large hydropower stations in India and China. Ultra high dc voltage (UHVDC) up to 800 kV is the preferred dc voltage level for these applications. Currently world-wide existing HVDC schemes are limited to maximum voltage levels of 500 kV to 600 kV. Therefore, the impact of increased ste...

متن کامل

Security and Stability Analysis for Yunnan Power Grid with Wind Power Integration

Wind power is sustainable, renewable and clean energy. There are abundant wind resources in Yunnan province, China. In recent years, wind power integration has developed rapidly in Yunnan province. With the first batch of the wind farm being built and a part of them going into production in Yunnan, the wind power resources will be large-scale developed and utilized in the future. Based on the w...

متن کامل

بهبود پایداری شبکه قدرت با روش جدید حذف بار ترکیبی

Power system blackouts have become a serious problem for electric utilities especially in recent years. Different forms of system instability have emerged in recent blackouts, such as voltage instability and frequency instability. To counteract each form of system instability, special algorithms have been designed in the protection system, e.g. Under Frequency Load Shedding (UFLS) and Under Vol...

متن کامل

Reliability Improvement Strategies for HVDC Transmission System

This paper analyses reliability data of HVDC systems of Southern China Power Grid. The weak links of HVDC systems’ operational reliability are DC control and protection, valve hall and valve cooling system and transmission lines. Some improvement measures and HVDC system reliability technology are proposed in this paper.

متن کامل

Induction of radioresistant nasopharyngeal carcinoma cell line CNE-2R by repeated high-dose X-ray irradiation

Background: All To enhance the curative effect of radiotherapy, we established a radio-resistant cell line, CNE-2R from CNE-2, a radio-sensitive type of CNE, through repeated irradiation. The developed cell line provides a basis for further studies on the radio-resistance of CNE and the molecular mechanism of radiotherapy sensitization drugs. Materials and Methods: The CNE-2 cell line was selec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013