Experimental testing is widely used to predict wear of total knee replacement (TKR) devices. Computational models cannot replace this essential in vitro testing, but they do have complementary strengths and capabilities, which make in silico models a valuable support tool for experimental wear investigations. For effective exploitation, these two separate domains should be closely corroborated together; this requires extensive data-sharing and cross-checking at every stage of simulation and testing. However, isolated deterministic corroborations provide only a partial perspective; in vitro testing is inherently variable, and relatively small changes in the environmental and kinematic conditions at the articulating interface can account for considerable variation in the reported wear rates. Understanding these variations will be key to managing uncertainty in the tests, resulting in a 'cleaner' investigation environment for further refining current theories of wear. This study demonstrates the value of probabilistic in silico methods by describing a specific, targeted corroboration of the AMTI knee wear simulator, using rigid body dynamics software models. A deterministic model of the simulator under displacement-control was created for investigation. Firstly, a large sample of experimental data (N>100) was collated, and a probabilistic computational study (N>1000 trials) was used to compare the kinetic performance envelopes for in vitro and in silico models, to more fully corroborate the mechanical model. Secondly, corresponding theoretical wear-rate predictions were compared to the experimentally reported wear data, to assess the robustness of current wear theories to uncertainty (as distinct from the mechanical variability). The results reveal a good corroboration for the physical mechanics of the wear test rig; however they demonstrate that the distributions for wear are not currently well-predicted. The probabilistic domain is found to be far more sensitive at distinguishing between different wear theories. As such we recommend that in future, researchers move towards probabilistic studies as a preferred framework for investigations into implant wear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-silico wear prediction for knee replacements--methodology and corroboration.

The capability to predict in-vivo wear of knee replacements is a valuable pre-clinical analysis tool for implant designers. Traditionally, time-consuming experimental tests provided the principal means of investigating wear. Today, computational models offer an alternative. However, the validity of these models has not been demonstrated across a range of designs and test conditions, and several...

متن کامل

Doctor of Philosophy ENHANCED PRE - CLINICAL ASSESSMENT OF TOTAL KNEE REPLACEMENT USING

FACULTY OF ENGINEERING, SCIENCE & MATHEMATICS SCHOOL OF ENGINEERING SCIENCES Doctor of Philosophy ENHANCED PRE-CLINICAL ASSESSMENT OF TOTAL KNEE REPLACEMENT USING COMPUTATIONAL MODELLING WITH EXPERIMENTAL CORROBORATION & PROBABILISTIC APPLICATIONS by Anthony Michael Strickland Demand for Total Knee Replacement (TKR) surgery is high and rising; not just in numbers of procedures, but in the diver...

متن کامل

Comparison of Two Probabilistic Methods for Finite Element Analysis of Total Knee Replacement

Probabilistic Finite Element (FE) models have recently been developed to assess the impact of experimental variability present in knee wear simulator on predicted Total Knee Replacement (TKR) mechanics by determining the performance envelope of joint kinematics and contact mechanics. The gold standard for this type of analysis is currently the Monte Carlo method, however, this requires a larger...

متن کامل

Advanced Dynamic Simulation of Membrane Desalination Modules Accounting for Organic Fouling

A reliable dynamic simulator (based on a sound process model) is highly desirable for optimizing the performance of individual membrane modules and of entire desalination plants. This paper reports on progress toward development of a comprehensive model of the complicated physical-chemical processes occurring in spiral wound membrane (SWM) modules, that accounts for the...

متن کامل

Effect of joint laxity on polyethylene wear in total knee replacement.

Experimental simulator studies are frequently performed to evaluate wear behavior in total knee replacement. It is vital that the simulation conditions match the physiological situation as closely as possible. To date, few experimental wear studies have examined the effects of joint laxity on wear and joint kinematics and the absence of the anterior cruciate ligament has not been sufficiently t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 2011