Selection of weighting factors for quantification of PET radioligand binding using simplified reference tissue models with noisy input functions.

نویسندگان

  • M D Normandin
  • R A Koeppe
  • E D Morris
چکیده

Input function noise contributes to model-predicted values and should be accounted for during parameter estimation. This problem has been examined in the context of PET data analysis using a noisy image-derived arterial input function. Huesman and Mazoyer (1987 Phys. Med. Biol 32 1569-79) incorporated the effect of error in the measured input function into the objective function and observed a subsequent improvement in the accuracy of parameters estimated from a kinetic model of cardiac blood flow. Such a treatment has not been applied to the reference region models commonly used to analyze dynamic positron emission tomography data with receptor-ligand tracers. Here, we propose a strategy for selection of weighting factors that accounts for noise in the reference region input function and test the method on two common formulations of the simplified reference tissue model (SRTM). We present a simulation study which demonstrates that the proposed weighting approach improves the accuracy of estimated binding potential at high noise levels and when the reference tissue and target regions of interest are of comparable size. In the second simulation experiment, we show that using a small, homogeneous reference tissue with our weighting technique may have advantages over input functions derived from a larger (and thus less noisy), heterogeneous region with conventional weighting. A comparative analysis of clinical [(11)C]flumazenil data found a small but significant increase in estimated binding potential when using the proposed weighting method, consistent with the finding of reduced negative bias in our simulation study. The weighting strategy described here accounts for noise in the reference region input function and may improve the performance of the SRTM in applications where data are noisy and the reference region is relatively small. This technique may offer similar benefits to other models using reference region inputs, particularly those derived from the SRTM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic modeling of 11C-SB207145 binding to 5-HT4 receptors in the human brain in vivo.

UNLABELLED The serotonin 4 receptor (5-HT(4) receptor) is known to be involved in learning and memory. We evaluated for the first time the quantification of a novel 5-HT(4) receptor radioligand, (11)C-SB207145, for in vivo brain imaging with PET in humans. METHODS For evaluation of reproducibility, 6 subjects were scanned twice with (11)C-SB207145 on the same day. A further 2 subjects were sc...

متن کامل

Tracer kinetic modeling of [(11)C]AFM, a new PET imaging agent for the serotonin transporter.

[(11)C]AFM, or [(11)C]2-[2-(dimethylaminomethyl)phenylthio]-5-fluoromethylphenylamine, is a new positron emission tomography (PET) radioligand with high affinity and selectivity for the serotonin transporter (SERT). The purpose of this study was to determine the most appropriate kinetic model to quantify [(11)C]AFM binding in the healthy human brain. Positron emission tomography data and arteri...

متن کامل

Evaluation of the novel 5-HT4 receptor PET ligand [11C]SB207145 in the Göttingen minipig.

This study investigates 5-hydroxytryptamine 4 (5-HT(4)) receptor binding in the minipig brain with positron emission tomography (PET), tissue homogenate-binding assays, and autoradiography in vitro. The cerebral uptake and binding of the novel 5-HT(4) receptor radioligand [(11)C]SB207145 in vivo was modelled and the outcome compared with postmortem receptor binding. Different models for quantif...

متن کامل

Kinetic modeling of the serotonin 5-HT(1B) receptor radioligand [(11)C]P943 in humans.

[(11)C]P943 is a new radioligand recently developed to image and quantify serotonin 5-Hydroxytryptamine (5-HT(1B)) receptors with positron emission tomography (PET). The purpose of this study was to evaluate [(11)C]P943 for this application in humans, and to determine the most suitable quantification method. Positron emission tomography data and arterial input function measurements were acquire...

متن کامل

Imaging of the striatal and extrastriatal dopamine transporter with (18)F-LBT-999: quantification, biodistribution, and radiation dosimetry in nonhuman primates.

UNLABELLED The aim of this study was to evaluate the quantification, biodistribution, and radiation dosimetry of the novel dopamine transporter (DAT) radioligand (18)F-(2S,3S)-methyl 8-((E)-4-fluorobut-2-en-1-yl)-3-(p-tolyl)-8-azabicyclo[3.2.1]octane-2-carboxylate ((18)F-LBT-999) in nonhuman primates. METHODS The brain study was conducted in 4 female rhesus monkeys. PET measurements were cond...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2012