Generalized Penalized Weighted Least-Squares Reconstruction for Deblurred Flat-Panel CBCT

نویسنده

  • Steven Tilley
چکیده

An increase in achievable spatial resolution would enable application of flat-panel detector cone-beam CT (FPCBCT) in high-resolution applications, such as 3D breast and bone imaging. Improved reconstruction techniques exploiting more sophisticated models of noise and spatial resolution characteristics may provide such improvement. In this work, we propose a statistical model of measurement mean and covariance, with particular attention given to correlations in measurement data. An iterative reconstruction algorithm based on this model was applied to simulated and real experimental data to evaluate its performance compared to an uncorrelated model under various imaging conditions. Focal spot and detector blur of a CBCT testbench were measured and used to inform the model-based image reconstruction. Simulation studies demonstrate that incorporation of the correlated noise model yields improved reconstructions, especially in the presence of focal spot blur. Improved noise-resolution tradeoffs were quantified, and application to high-resolution imaging of trabecular bone was

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regularization Design for High-Quality Cone-Beam CT of Intracranial Hemorrhage using Statistical Reconstruction

Intracranial hemorrhage (ICH) is associated with pathologies such as hemorrhagic stroke and traumatic brain injury. Multi-detector CT is the current front-line imaging modality for detecting ICH (fresh blood contrast 40-80 HU, down to 1 mm). Flat-panel detector (FPD) cone-beam CT (CBCT) offers a potential alternative with a smaller scanner footprint, greater portability, and lower cost potentia...

متن کامل

Iterative image reconstruction for CBCT using edge-preserving prior.

On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To re...

متن کامل

Iterative CT Reconstruction using Models of Source and Detector Blur and Correlated Noise.

Statistical model-based reconstruction methods derive much of their advantage over traditional methods through more accurate forward models of the imaging system. Typical forward models fail to integrate two important aspects of real imaging systems: system blur and noise correlations in the measurements. This work develops an approach that models both aspects using a two-stage approach that in...

متن کامل

Uniform CR Bound: Implement ation Issues And Applications

We apply a uniform Cramer-Rao (CR) bound [l] to study the bias-variance trade-offs in single photon emission computed tomography (SPECT) image reconstruction. The uniform CR bound is used to specify achievable and unachievable regions in the bias-variance trade-off plane. The image reconstruction algorithms considered in this paper are: 1) Space alternating generalized EM and 2) penalized weigh...

متن کامل

Spatial Resolution Properties of Penalized Weighted Least-squares Tomographic Image Reconstruction with Model Mismatch

This paper presents an analysis of the spatial resolution properties of tomographic image reconstruction based on a regularized least-squares objective function. The derivations are based on an idealized space-invariant tomographic system having a continuum of radial and angular samples. The analysis accounts for mismatch between the true radial point-spread function (PSF) of the measurements a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015