Comments on “K. L. Cheng, Capacitor Theory for Nonfaradaic Potentiometry. Microchemical Journal 1990, 42, 524” and Reply to “Comments on ‘E. Pungor, The New Theory of Ion Selective Electrodes. Sensors 2001, 1, 1-12’ ”

نویسنده

  • Ernõ Pungor
چکیده

I have sent the cited article [1] to the Sensors as a summing contribution, to inform those working in the field of ISE about my results coming from approximately 30 years of research activity. Thus far I used to send detailed publications to newspapers with a wider range of interests. At the time when I was publishing the first ion-selective electrode outside of glass-electrode [2], it was a general opinion that ions diffuse through the membrane. This was contradicted by the first response-time measurements, which were later further strengthened [3,4]. Conversely to the many times published response-time measurements, we did not use the response-time measurement of electrochemical cells, but the reaction occurring on the measuring electrode. The response-time of the later system is about 20-40 milliseconds. Further investigations certified that the potential-signal appeared only by the surface reactions [5,6]. The question of the surface reaction was confirmed by glass-electrodes as well [7]. In the published article [1] the phenomena were explained through a chemical approach. Cheng's approach [8] is very good; he used a physical model for this. These two do not oppose to each other. We had published already in the 80's that the potential is defined by the surface reactions. The acceptation of this idea has been accepted in the literature as well. Figures, analogue to that adopted from Professor Buck were already published long before in the papers of Simon [9] and his colleges in 1972, and therefore I did not think, any rights would valid to this.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comments on “E. Pungor, The New Theory of Ion Selective Electrodes. Sensors 2001, 1, 1-12”

The techniques and information described in this paper [1] are nothing new. For instance, memory effect, x-ray photoelectron spectroscopy, no ion penetration from the membrane surface to the inside membrane, the K + adsorption at the valinomycin, etc. are well known [2]. In particular, the author did not cite many references for the information. For instance, the K + and membrane graph (Fig. 1)...

متن کامل

Potassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives

Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...

متن کامل

Ion Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation

Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...

متن کامل

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

Modern Directions for Potentiometric Sensors.

This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the underlying membrane processes. The recent developments in lowering the detection ...