Delivery from episcleral exoplants.

نویسندگان

  • Ricardo A Pontes de Carvalho
  • Melissa L Krausse
  • A Linn Murphree
  • Edward E Schmitt
  • Peter A Campochiaro
  • Irene H Maumenee
چکیده

PURPOSE To assess the impact of an episcleral exoplant on transscleral delivery. METHODS New Zealand White rabbits were given a periocular injection of sodium fluorescein (fluorescein, 376 Da) or an episcleral exoplant loaded with fluorescein. Two types of exoplants were tested: (1) a rigid polyethylene device, impermeable on one side and open to the sclera on the other, that contained compressed pellets of fluorescein and was sutured loosely (apposition group) or tightly to indent the sclera (indentation group) and (2) flexible refillable silicone exoplants also open to the sclera that were secured by suturing, to form a sealed episcleral chamber that was filled with a fluorescein solution. Ocular and plasma fluorophotometry were performed at several time points, and histology was performed to evaluate the effect of exoplants on the periocular tissue. RESULTS Within 20 minutes of a periocular injection of fluorescein, peak fluorescence was visible in the anterior chamber (AC) and at later time points was displaced toward the retina; at all time points, the highest fluorescence was in the AC. For the polyethylene device indentation group, peak fluorescence was in the retina and posterior vitreous and spread to the AC over time. For the apposition exoplant group, two peaks of fluorescence were seen initially, one in the retina and posterior vitreous and one in the AC. The area under the concentration time curve (AUC +/- SE) for fluorescein concentration was 144.4 +/- 15.1 mug . h/mL for the retinal peak and 43.6 +/- 7.1 mug . h/mL for the posterior vitreous peak after injection of 5 mg of fluorescein into a silicone exoplant, compared with a retinal peak of 3.9 +/- 0.3 and a posterior vitreous peak of 0.99 +/- 0.26 mug . h/mL after periocular injection of 5 mg of fluorescein (P < 0.01 for each). Peak plasma fluorescein levels were significantly reduced in the exoplant group compared with periocular injection. CONCLUSIONS An episcleral exoplant facilitates diffusion of fluorescein through the sclera resulting in high levels in the retina and posterior vitreous; levels are markedly increased compared with periocular injection of the same amount of fluorescein. It also reduces peak plasma levels indicating reduction of systemic absorption. This procedure provides a new approach that can be combined with sustained-release preparations to optimize delivery of agents to the retina and choroid while minimizing the potential for systemic toxicity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of drug delivery to the posterior pole of the rabbit eye with an episcleral implant.

PURPOSE To evaluate the feasibility of a nonbiodegradable polymeric episcleral implant as a new controlled intraocular delivery system of betamethasone (BM) to the posterior pole of the eye. METHODS The episcleral implant, which is composed of a drug-releasing component and a suture tag, released BM through an ethylene vinyl acetate membrane. The implants were placed on the sclera in 12 eyes ...

متن کامل

Sustained release of carmustine (BCNU) for treatment of experimental intraocular malignancy.

Sustained release of carmustine (1,3-bis[2-chloroethyl]-1-nitrosourea, or BCNU) via an episcleral implanted silicone device was used to treat Greene hamster melanoma implanted in the anterior chamber of rabbit eyes. Group 1 animals received carmustine intravenously; group 2 received the drug by local sustained release via an episcleral implanted silicone device; group 3 received the drug by bot...

متن کامل

Evaluation of clearance mechanisms with transscleral drug delivery.

PURPOSE The goal of this study was to examine elimination pathways when delivering subconjunctivally administered hydrophilic agents to the retinas of rat eyes. METHODS The distribution of sodium fluorescein released from an episcleral implant was compared in live and postmortem eyes. Elimination of the subconjunctivally administered hydrophilic agent IgG through blood and lymphatic vessels w...

متن کامل

A novel bioerodible deep scleral lamellar cyclosporine implant for uveitis.

PURPOSE To determine the feasibility, safety, and effectiveness of an episcleral or deep scleral lamellar sustained release cyclosporine (CsA) device in a naturally occurring animal model of uveitis. METHODS A two-compartment perfusion chamber was used to assess in vitro human and equine scleral permeability of fluorescein, dexamethasone-fluorescein, or CsA. A biodegradable, matrix-reservoir ...

متن کامل

EPISCLERAL VENOUS PRESSURE IN TONOGRAPHY * t BY ARTHUR

DURING the 11 years in which the clinical measurement of facility of outflow by means of tonography has been practised, various workers have sought to elucidate and correct the sources of error inherent in this method. One of the assumptions originally made concerning tonography was that the episcleral venous pressure was not disturbed during the measurement. Friedenwald (Grant, 1951) and Becke...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 47 10  شماره 

صفحات  -

تاریخ انتشار 2006