Novel utilization of 3D technology and the hybrid operating theatre: Peri-operative assessment of posterior sterno-clavicular dislocation using cone beam CT

نویسندگان

  • James A Crowhurst
  • Douglas Campbell
  • Mark Whitby
  • Pavthrun Pathmanathan
چکیده

A patient with a medial and posterior dislocation of the right sterno-clavicular (SC) joint and displacement of the trachea and brachiocephalic artery by the medial head of the clavicle underwent general anaesthetic in the operating theatre for an open reduction procedure. The surgeon initially attempted a closed reduction, but this required imaging to check SC alignment. The patient was transferred to an adjacent hybrid operating theatre for imaging. Cone beam computed tomography (CBCT) was performed, which successfully demonstrated a significant reduction in the dislocation of the SC joint. The trachea and brachiocephalic artery were no longer compressed or displaced. This case study demonstrates an alternative to the patient being transferred to the medical imaging department for multi-slice CT. It also describes a novel use of the hybrid operating theatre and its CBCT capabilities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Accessory Mental Foramen by Cone-Beam Computed Tomography

Introduction: Any foramen in the buccal surface of mandibular body that transfers mental nerve and vessels except mental foramen, is called Accessory Mental Foramen (AMF). The objective of this study was the determination of the AMF using cone-beam computed tomography (CBCT). Materials and Methods:  this descriptive study was done on 180 CBCT projections which were selected by convenience samp...

متن کامل

The Operative Treatment of Bipolar Clavicular Dislocation: A Case Report

Introduction: Simultaneous bipolar dislocation of the clavicle is uncommon and unusual, although it has been documented as panclavicular dislocation, floating clavicle, and complete dislocation of the clavicle. A review of the recent literature indicated that most bipolar clavicular dislocations have been treated non-operatively. Case Report: We report the case of a 23 year polytrauma patient w...

متن کامل

Operative Treatment of Bipolar Clavicular Dislocation: A Case Report

INTRODUCTION Simultaneous bipolar dislocation of the clavicle is uncommon and unusual, although it has been documented as panclavicular dislocation, floating clavicle, and complete dislocation of the clavicle. A review of the recent literature indicated that most bipolar clavicular dislocations have been treated non-operatively. CASE REPORT We report the case of a 23 year polytrauma patient w...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 60  شماره 

صفحات  -

تاریخ انتشار 2013