The Effects of the Span Configurations and Conductor Sag on the Magnetic - Field Distribution under Overhead Transmission
نویسنده
چکیده
Copyright 1996-2012 Researchpub.org. All rights Reserved. 11 Abstract— Ground level electric and magnetic-fields from overhead power transmission lines are of increasingly important considerations in several research areas due to their impact on health and environmental issues. The paper presents a more generalized technique to calculate the magnetic-field generated by power transmission lines in three dimension coordinates. This technique has been evolved, formulated, analyzed and applied to a suggested 500-kV single circuit transmission line to evaluate the effects of line topology and terrain topography on the computed magnetic-field. The results are compared with two-dimensions technique.
منابع مشابه
Simulation of Single Conductors Galloping Oscillations and Estimation of their Maximum Amplitudes
Overhead transmission lines are influenced by different factors which are mostly electrical and mechanical. These factors can cause problems for lines, distortions in network and outage of line. In designing transmission lines mechanical properties are evaluated after selecting a suitable conductor and clearance with regard to electrical properties. In lines designing, an important mechanical p...
متن کاملVoltage Sag in Distribution Systems- A review and comparative study (Reasons, Characteristics, Compensations and Detection)
By quick technological advancements in industrial control processes, major industries demand higher power quality. According to IEEE 1159-1995 standard, any problems in voltage, current or frequency that lead to the error or malfunctions in electrical equipment are considered as a power quality problem. Among the power quality phenomena, voltage sag has been an important problem for power sys...
متن کاملTransient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA
In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...
متن کاملSimulation of Single Conductors Galloping Oscillations and Estimation of their Maximum Amplitudes
Overhead transmission lines are influenced by different factors which are mostly electrical and mechanical. These factors can cause problems for lines, distortions in network and outage of line. In designing transmission lines mechanical properties are evaluated after selecting a suitable conductor and clearance with regard to electrical properties. In lines designing, an important mechanical p...
متن کاملApplication of GPS for Sag Measurement of Overhead Power Transmission Line
Overhead conductor sag may be measured by different methods. In the paper measurement of sag of 66KV power transmission line under shut down conditions at no wind load using standard handheld GPS receiver BT 359 has done. The real time direct measurement of overhead conductor sag is needed for the operation of power transmission system. The measurement of conductor tension, temperature and ambi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -