Injectable silicone rubber for ocular implantation after evisceration

نویسندگان

  • Peng Fei Zheng
  • Qi Sheng You
  • Qian Li
  • Hong Yan Deng
  • Ian Y H Wong
  • Xiao Yan Peng
چکیده

OBJECTIVE To investigate the usefulness of addition type liquid silicone rubber (ATLSR) as injectable implant after evisceration to maintain the eyeball volume in an animal experiment. METHODS Twelve adult New Zealand white rabbits were included. One eye of each rabbit was randomly selected for evisceration with the fellow eye as control. ATLSR was injected to fill the eyeball socket after evisceration. In vivo observation and photographs were performed up to 24 weeks post-op. Two rabbits were sacrificed respectively at post-operative week 1, 2, 4, 8, 12 and 24. After enucleation, the vertical, horizontal and sagittal diameters of the experimental eyeballs were measured and compared with the control eyes. Histopathological studies were performed to evaluate signs of inflammation. RESULTS Cornea remained clear throughout the observation period despite mild epithelial edema and neovascularization. Compared to the control eyes, the experimental eyes were significantly smaller in vertical diameter (17.00±1.17 vs. 17.54±1.11 mm, P<0.001), but larger in sagittal diameter (16.85±1.48 vs. 16.40±1.38 mm, P = 0.008), and had no significant difference in horizontal diameter (17.49±1.53 vs. 17.64±1.21 mm, P = 0.34). Postoperative inflammation was observed at one week after surgery, which peaked at 2-3 weeks, then regressed gradually. At week 12 and week 24, most of the inflammatory cells disappeared with some residual plasma cells and eosinophils. CONCLUSION Injectable addition type silicon rubber may be a good choice for ocular implantation after evisceration, maintaining eyeball volume and cosmetically satisfactory when compared to the fellow eye. Spontaneous regression of inflammation implied good biocompatibility for at least 24 weeks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bridging Small-Gap Peripheral Nerve Defect Using Silicone Rubber Chamber in the Rat Sciatic Nerve Transection Model

  Despite promising results observed using silicone rubber chamber, no previous comprehensive work was performed on behavior of the conduit. Present study aimed at further functional, histomorphometrical and immunohistochemical assessment of nerve regeneration in the same animal along a 10-mm rat sciatic nerve gap. Fifty- four male Wistar rats were divided into three experimental groups (n = 1...

متن کامل

Surface Modification of Silicone Rubber by Ion Implantation to Improve Biocompatibility

Silicone Rubber (SR) and SR-based materials have been used as medical tissue implants in the field of plastic surgery for many years, but there are still some reports of adverse reactions to long-term implants. In our study, three types of carbon ion silicone rubber were obtained by implanting three doses of carbon ions. Then, the surface characteristics, the antibacterial adhesion properties a...

متن کامل

ß-tricalcium Phosphate Granules as an Alternative Material for Ocular Implantation

Background: Some types of implants used for orbital implantation have side effects and complications. In this study we have evaluated beta-tricalcium phosphate (ß-TCP: ChronOS) granules as an orbital implant. Methods: Eighteen rabbits randomly allocated to four groups. Right eye enucleation performed in groups I to III followed by filling with autologous bone particles (n=5), a mixture of autol...

متن کامل

Biofunctionalization of silicone rubber with microgroove-patterned surface and carbon-ion implantation to enhance biocompatibility and reduce capsule formation

PURPOSE Silicone rubber implants have been widely used to repair soft tissue defects and deformities. However, poor biocompatibility can elicit capsule formation, usually resulting in prosthesis contracture and displacement in long-term usage. To overcome this problem, this study investigated the properties of silicone rubber materials with or without a microgroove-patterned surface and with or...

متن کامل

Silicone implant to extra-ocular muscles.

A PROCEDURE which would allow the lengthening of an extra-ocular muscle beyond that which is usually obtained from the conventional surgical techniques would be of definite advantage in large-angle strabismus and strabismus fixus. Since silicone rubber is well tolerated by ocular and non-ocular tissues, the implantation of a small, thin sheet of this material to lengthen an extra-ocular muscle ...