Temporal variability in urinary excretion of bisphenol A and seven other phenols in spot, morning, and 24-h urine samples.

نویسندگان

  • Tina Harmer Lassen
  • Hanne Frederiksen
  • Tina Kold Jensen
  • Jørgen Holm Petersen
  • Katharina M Main
  • Niels E Skakkebæk
  • Niels Jørgensen
  • Selma Kløve Kranich
  • Anna-Maria Andersson
چکیده

Human exposure to modern non-persistent chemicals is difficult to ascertain in epidemiological studies as exposure patterns and excretion rates may show temporal and diurnal variations. The aim of this study was to assess the temporal variability in repeated measurements of urinary excretion of bisphenol A (BPA) and seven other phenols. All analytes were determined using TurboFlow-LC-MS/MS. Two spot, three first morning and three 24-h urine samples were collected from 33 young Danish men over a three months period. Temporal variability was estimated by means of intraclass correlation coefficients (ICCs). More than 70% of the urine samples had detectable levels of BPA, triclosan (TCS), benzophenone-3 (BP-3) and sum of 2,4-dichlorophenol and 2,5-dichlorophenol (ΣDCP). We found low to moderate ICCs for BPA (0.10-0.42) and ΣDCP (0.39-0.72), whereas the ICCs for BP-3 (0.69-0.80) and TCS (0.55-0.90) were higher. The ICCs were highest for the two spot urine samples, which were collected approximately 4 days apart, compared with the 24-h urine samples and the first morning urine samples, which were collected approximately 40 days apart. A consequence of the considerable variability in urinary excretion of BPA may be misclassification of individual BPA exposure level in epidemiological studies, which may lead to attenuation of the association between BPA and outcomes. Our data do not support that collection of 24-h samples will improve individual exposure assessment for any of the analysed phenols.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of Urinary Concentrations of Bisphenol A in Spot Samples, First Morning Voids, and 24-Hour Collections

BACKGROUND Human exposure to bisphenol A (BPA) is widespread. After exposure, BPA is rapidly metabolized and eliminated in urine. Therefore, there is considerable within-person and between-person variability of BPA concentrations in spot urine samples. However, no information exists on the within-day variability of urinary BPA concentrations. OBJECTIVES We examined the between-person and with...

متن کامل

First morning voids are more reliable than spot urine samples to assess microalbuminuria.

Measurement of urinary albumin excretion (UAE) in a 24-h collection is the gold standard method to determine the presence of microalbuminuria. We sought to compare more practical alternatives--measurement of urinary albumin concentration (UAC) or albumin:creatinine ratio (ACR)--in a first morning void or in a spot urine sample with this gold standard. We asked 241 participants of a prospective ...

متن کامل

Within-person reproducibility of urinary bisphenol A and phthalate metabolites over a 1 to 3 year period among women in the Nurses’ Health Studies: a prospective cohort study

BACKGROUND Associations of bisphenol A and phthalates with chronic disease health outcomes are increasingly being investigated in epidemiologic studies. The majority of previous studies of within-person variability in urinary bisphenol A and phthalate metabolite concentrations have focused on reproducibility over short time periods. Long-term reproducibility data are needed to assess the potent...

متن کامل

Quantification of Proteinuria with Urinary Protein to Osmolality Ratios in Children

Background: The ratio of urine protein to urine osmolality has recently been suggested as an accurate method to determine proteinuria.  Objective: We studied the correlation of urine protein to urine osmolality ratio with 24-hr urinary protein excretion. Methods: 150 children aged 0.11–17 years admitted to the Department of Pediatric Nephrology were included in this study. Early morning urine s...

متن کامل

مقایســه اندازه‌گیری سطح آلبومین به روش ایمونوتوربیدومتری در ســه شیوه مختلف نـمونه‌گیری ادراری برای غربالگری آلبومینوری در بیماران دیابتی

 Background: Microalbominuria (MA) is early presentation of renal damage which acts as an independent factor of cardiovascular events in these patients. There are various methods for sampling and also different laboratory tests to measuring albominuria. The aim of this study was to compare of different urine collection methods for measuring albominuria using immunoturbidometry assay which has a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Environmental research

دوره 126  شماره 

صفحات  -

تاریخ انتشار 2013