Thin-section CT findings in peripheral lung cancer of 3 cm or smaller: are there any characteristic features for predicting tumor histology or do they depend only on tumor size?

نویسندگان

  • Binghu Jiang
  • Shodayu Takashima
  • Chie Miyake
  • Tomoaki Hakucho
  • Yoshiyuki Takahashi
  • Daisuke Morimoto
  • Hodaka Numasaki
  • Katsuyuki Nakanishi
  • Yasuhiko Tomita
  • Masahiko Higashiyama
چکیده

BACKGROUND Ground-glass opacity (GGO) is reported to be characteristic to lepidic growth of neoplasm in subsolid nodules. In solid nodules of lung cancer, however, there is no characteristic feature to be reported. PURPOSE To study if there are any thin-section CT findings characteristic to tumor histology or if they are only related to tumor size in solid nodules of the lung cancer. MATERIAL AND METHODS This study included 106 solid peripheral lung cancers of 3 cm or smaller (56 adenocarcinomas, 33 squamous cell carcinomas, and 17 small cell carcinomas) in which 16-slice CT with 1 mm collimation was performed before surgery. Six morphologic findings (presence or absence of lobulation, coarse spiculation, air bronchogram, cavity, pleural tag, and pleural-based lesion) and four measurements (ratio of the greatest transverse and vertical diameter to the shortest transverse diameter and density of lobulation and coarse spiculation) on thin-section CT images were evaluated. Density of lobulation (coarse spiculation) was defined as the ratio of lobulation (coarse spiculation) number to the greatest transverse diameter of a nodule. RESULTS Air bronchogram (P < 0.01) was the only significant factor for predicting lung adenocarcinoma. The prevalence of air bronchogram was significantly greater in adenocarcinoma than in squamous cell carcinoma (P < 0.01) or small cell carcinoma (P < 0.01). As the tumor size advanced, significantly positive linear trends were seen in the prevalence of lobulation (P < 0.01), coarse spiculation (P < 0.01), and pleural tag (P < 0.01), and the mean values of density of lobulation (P < 0.01) and coarse spiculation (P < 0.01), while the significant negative linear trend was seen in the ratio of vertical diameter to the shortest transverse (P = 0.02). CONCLUSION Air bronchogram on thin-section CT is characteristic feature of solid adenocarcinoma of the lung. However, other thin-section CT findings are irrelevant to tumor histology and related only to tumor size.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

Intrathoracic Malignant Peripheral Nerve Sheath Tumor: Histopathological and Immunohistochemical Features

Malignant peripheral nerve sheath tumor (MPNST) is a rare nerve sheath tumor derived from Schwann cells or pleuripotent cells of neural crest. Neurogenic tumors make about 10-20% of all mediastinal tumors. Incidence of MPNST is 0.001% in general population and 0.16% in patients with neurofibromatosis I (NF I). We report a case of 60 year female presenting with progressive cough and breathlessne...

متن کامل

Calculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP

Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...

متن کامل

WRAP53 Polymorphism, rs2287498: A Case Study in Northwest of Iran?

Background: Non-coding RNAs apply regulations on expression or function of a gene. A class of non-coding RNAs, natural antisense transcripts, might overlap with their flanking genes and emerge a new complexity upon regulation. WRAP53, is a natural antisense transcript overlapped in a head-to-head manner on the opposite strand of TP53. It has 3 transcripts of which WRAP53β produ...

متن کامل

Comparison of brain SPECT with 99mTc-MIBI and CT-scan in discriminating of radiation necrosis and brain tumor recurrence [Persian]

Introduction: 99mTc-MIBI has been proposed for use as an imaging agent for various tumors, including breast cancer, lung cancer, lymphomas, melanomas and brain neoplastic lesions. Brain tumors are very common and radiotherapy being major part of treatment following surgery. After radiotherapy, deteriorating clinical status can be due to either radiation necrosis or recurrent tumor. Comput...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta radiologica

دوره 55 3  شماره 

صفحات  -

تاریخ انتشار 2014