The Polyvinyl Alcohol Sponge Model Implantation

نویسندگان

  • Desirae L. Deskins
  • Shidrokh Ardestani
  • Pampee P. Young
چکیده

Wound healing is a complicated, multistep process involving many cell types, growth factors and compounds(1-3). Because of this complexity, wound healing studies are most comprehensive when carried out in vivo. There are many in vivo models available to study acute wound healing, including incisional, excisional, dead space, and burns. Dead space models are artificial, porous implants which are used to study tissue formation and the effects of substances on the wound. Some of the commonly used dead space models include polyvinyl alcohol (PVA) sponges, steel wire mesh cylinders, expanded polytetrafluoroethylene (ePTFE) material, and the Cellstick(1,2). Each dead space model has its own limitations based on its material's composition and implantation methods. The steel wire mesh cylinder model has a lag phase of infiltration after implantation and requires a long amount of time before granulation tissue formation begins(1). Later stages of wound healing are best analyzed using the ePTFE model(1,4). The Cellstick is a cellulose sponge inside a silicon tube model which is typically used for studying human surgery wounds and wound fluid(2). The PVA sponge is limited to acute studies because with time it begins to provoke a foreign body response which causes a giant cell reaction in the animal(5). Unlike other materials, PVA sponges are easy to insert and remove, made of inert and non-biodegradable materials and yet are soft enough to be sectioned for histological analysis(2,5). In wound healing the PVA sponge is very useful for analyzing granulation tissue formation, collagen deposition, wound fluid composition, and the effects of substances on the healing process(1,2,5). In addition to its use in studying a wide array of attributes of wound healing, the PVA sponge has also been used in many other types of studies. It has been utilized to investigate tumor angiogenesis, drug delivery and stem cell survival and engraftment(1,2,6,7). With its great alterability, prior extensive use, and reproducible results, the PVA sponge is an ideal model for many studies(1,2). Here, we will describe the preparation, implantation and retrieval of PVA sponge disks (Figure 1) in a mouse model of wound healing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Response of the Cornea to Implantation of Polyvinyl Alcohol Sponge.

-he biochemical study of wound healing of the cornea has been neglected largely because of the difficulties entailed in isolating adequate amounts of newly formed tissue for chemical analysis. Studies of corneal wound healing have as a result been mainly of a histologic and autoradiographic nature." Although the micromethods of Anseth for the separation and characterization of the polysaccharid...

متن کامل

Silastic Molding Method for Pectus Excavatum Correction Using a Polyvinyl Alcohol (Ivalon) Sponge

Pectus excavatum is rare, but it is the most common type of sternal congenital disorder. There are many surgical methods to correct pectus excavatum such as the Ravitch method, Wada method, Silastic mold method, and the Nuss operation. We report a case of minimal invasive surgery for pectus excavatum using a polyvinyl alcohol sponge.

متن کامل

Polyvinyl alcohol sponge for embolotherapy: particle size and morphology.

The size and morphology of particulate polyvinyl alcohol (PVA) sponge prepared by a blender technique for embolotherapy were analyzed by light and scanning electron microscopy. Techniques for preparation and sizing of PVA sponge particles are described. Two types of particulate material, differing in both size and morphology, were found. Large particles (greater than 50 micron) had irregular sh...

متن کامل

Modulation of macrophage phenotype by soluble product(s) released from neutrophils.

The regulation of macrophage phenotype by neutrophils was studied in the s.c. polyvinyl alcohol sponge wound model in mice made neutropenic by anti-Gr-1 Ab, as well as in cell culture. Wounds in neutropenic mice contained 100-fold fewer neutrophils than those in nonneutropenic controls 1 day after sponge implantation. Wound fluids from neutropenic mice contained 68% more TNF-alpha, 168% more IL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 78  شماره 

صفحات  -

تاریخ انتشار 2012