Reproducibility of serial left ventricle perfusion, volume, and ejection fraction measurements using multiplexed multipinhole SPECT in healthy rats and rats after myocardial infarction.

نویسندگان

  • Jared H Strydhorst
  • Frans H Leenen
  • Terrence D Ruddy
  • R Glenn Wells
چکیده

UNLABELLED Assessment of small-animal cardiac data acquired using SPECT requires an accurate understanding of the reproducibility and the uncertainties associated with the technique. Furthermore, it is also useful to have a baseline of reference data against which to compare the outcome of a particular study. METHODS We scanned both healthy and post-myocardial infarction rats injected with (99m)Tc-tetrofosmin in a multidetector, multipinhole small-animal SPECT scanner. In this paper, we report on the creation of a reference database of the relative myocardial blood perfusion of rats. We also evaluated the reproducibility of perfusion measurements and measurements of left ventricle volume and ejection fraction, defined as the SD of a particular measurement repeated on the same animal or over multiple animals. RESULTS For the healthy rats, interscan reproducibility of volume measurements was 4%-7% of the total volume, and intersubject reproducibility was 9%-12% of the volume being measured. Interscan reproducibility remained unaffected after infarction (6%-8%), but intersubject reproducibility was much poorer (15%-26%). Ejection fraction in healthy animals was highly reproducible between scans and between rats: 3.1% and 3.3%, respectively. Interscan reproducibility of the postinfarction ejection fraction was 3.6%; intersubject reproducibility after infarction was 8.1%. CONCLUSION We have created a reference database for small-animal SPECT perfusion measurements in healthy male Sprague-Dawley rats and quantified the reproducibility of perfusion and functional measurement made with small-animal SPECT in healthy and postinfarction rats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

The effect of eight weeks of moderate-intensity endurance training on myocardial capillary density, ejection fraction and left ventricular shortening fraction in male rats with myocardial infarction

Background and objective: Vascular obstruction and impaired blood flow and oxygen delivery cause a myocardial infarction and limit a personchr('39')s function. Therefore, finding a way to create new arteries and replace blocked arteries has always been of interest to researchers, including exercise physiologists. Therefore, this study was conducted to evaluate the effect of eight weeks of moder...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2011