Chiron 800 system CO-oximeter module overestimates methemoglobin concentrations in neonatal samples containing fetal hemoglobin.
نویسندگان
چکیده
References 1. Wall RT, Harlan JM, Harker LA, Striker GE. Homocysteine-induced endothelial cell injury in vitro: a model for the study of vascular injury. Thromb Res 1980;18:113–21. 2. Nygard O, Nordrehaug JE, Refsum H, Ueland PM, Farstad M, Vollset SE. Plasma homocysteine levels and mortality in patients with coronary artery disease. N Engl J Med 1997;4:230–6. 3. Perry IJ, Refsum H, Morris RW, Ebrahim SB, Ueland PM, Shaper AG. Prospective study of serum total homocysteine concentration and risk of stroke in middle-aged British men. Lancet 1995;346:1395–8. 4. Fermo I, D’Angelo SV, Paroni R, Mazzola G, Calori G, D’Angelo A. Prevalence of moderate hyperhomocysteinemia in patients with early-onset venous and arterial occlusive disease. Ann Intern Med 1995;123:747–53. 5. Stabler SP, Marcell PD, Podell ER, Allen RH, Savage DG, Lindenbaum J. Elevation of total homocysteine in the serum of patients with cobalamin and folate deficiency detected by capillary gas chromatography-mass spectrometry. J Clin Invest 1988;81:466–74. 6. Chauveau P, Chadefaux B, Coude M, Aupetit J, Hannedouche T, Kamoun P, Jungers P. Increased plasma homocysteine concentration in patients with chronic renal failure. Miner Electrolyte Metab 1992;18:196–8. 7. Andersson A, Isaksson A, Hultberg B. Homocysteine export from erythrocytes and its implication for plasma sampling. Clin Chem 1992;38:1311–5. 8. Fiskerstrand T, Refsum H, Kvalheim G, Ueland PM. Homocysteine and other thiols in plasma and urine: automated determination and sample stability. Clin Chem 1993;39:263–71. 9. Ubbink JB, Vermaak WJH, Van der Merwe A, Becker PJ. The effect of blood sample aging and food consumption on plasma total homocysteine levels. Clin Chim Acta 1992;207:119–28. 10. Moller J, Rasmussen K. Homocysteine in plasma: stabilization of blood samples with fluoride. Clin Chem 1995;41:758–9. 11. Vester B, Rasmussen K. High performance liquid chromatography method for rapid and accurate determination of homocysteine in plasma and serum. Clin Chem 1991;29:549–4. 12. Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. J Clin Chem Clin Biochem 1983;21:709–20. 13. Nehler MR, Taylor ML, Porter JM. Homocysteinemia as a risk factor for atherosclerosis: a review. Cardiovasc Pathol 1997;6:1–9. 14. Refsum H, Fiskerstrand T, Guttormsen AB, Ueland PM. Assessment of homocysteine status. J Inher Metab Dis 1997;20:286–94. 15. Rasmussen K, Moller J, Lyngbak M, Holm Pedersen AM, Dybkjaer L. Ageand gender-specific reference intervals for total homocysteine and methylmalonic acid in plasma before and after vitamin supplementation. Clin Chem 1996;42:630–6.
منابع مشابه
Detection of H-ras mutations in urine sediments by a mutant-enriched PCR technique.
higher MetHb values in the presence of HbF. For MetHb concentrations of 15% or less, i.e., values most likely to be encountered clinically with NO therapy, the Corning 270, in agreement with the study carried out previously (5), was unaffected by the presence of HbF in the umbilical cord sample (P 5 0.7380). By contrast, the Chiron 800 showed a constant error to significantly higher MetHb (P 5 ...
متن کاملMeasurement of methemoglobin in neonatal samples containing fetal hemoglobin.
Because of the potential for methemoglobinemia during nitric oxide therapy in newborns, methods are needed to accurately quantify methemoglobin (MetHb) in the presence of the high concentrations of fetal hemoglobin (Hb F), bilirubin, and lipids seen in these patients. Spectral differences between fetal and adult Hbs invalidate assumptions of conventional multiwavelength Hb photometry, so we eva...
متن کاملCarboxyhemoglobin determined in neonatal blood with a CO-oximeter unaffected by fetal oxyhemoglobin.
Measurements of carboxyhemoglobin (COHb) for clinical purposes are routinely made with CO-oximeters. However, fetal hemoglobin (HbF) interferes with this spectrophotometric method. The manufacturer (Ciba Corning Diagnostics) of a new CO-oximeter (CCD 270) claims that COHb measurements with this instrument are insignificantly affected by HbF. We examined this claim through CO-oximeter analysis o...
متن کاملInterference of methylene blue with CO-Oximetry of hemoglobin derivatives.
Methylene blue (MB) is frequently used as an antidote in treating methemoglobinemia (1) because it facilitates the reducing activity of the NADPH-dependent methemoglobin reductase system in erythrocytes (2). However, MB absorbs strongly between 550 and 700 nm (Fig. 1 ), the same spectrophotometric region as that of the various hemoglobin derivatives: oxyhemoglobin (O2Hb), deoxyhemoglobin (HHb),...
متن کاملNotes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.
Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 44 7 شماره
صفحات -
تاریخ انتشار 1998