Effect of Posterior Dynamic Instrumentation on High-Intensity Zone in Lumbar Degenerative Disc Disease.

نویسندگان

  • Suat Canbay
  • Yaprak Ataker
  • Nazan Canbulat
  • Zeynep Unal Kabaoglu
  • Tunc Oktenoglu
  • Mehdi Sasani
  • Ali Fahir Ozer
چکیده

AIM To investigate high-intensity zone (HIZ) changes after lumbar posterior dynamic instrumentation. MATERIAL AND METHODS Our study included 53 patients: 27 patients in group 1, 26 patients in group 2. All patients had one or two levels of degenerative disc disease with an HIZ confirmed by magnetic resonance imaging (MRI). Group 1 underwent one- or two-level dynamic lumbar posterior instrumentation. Group 2 was treated conservatively with an exercise program. Patients were evaluated using MRI, a numerical visual analog pain scale (VAS), and the Oswestry Disability Index (ODI) at baseline, at 1 year after surgery, and at final follow-up evaluation. RESULTS The mean duration of follow-up was 49.3 months in group 1 and 47.19 months in group 2. The baseline VAS and ODI scores were similar for both groups. The mean VAS score of group 1 was significantly improved at 1 year after surgery and at final follow-up. The mean ODI value was lower in group 1 than in group 2 at 1 year and at final follow-up. Pfirrmann grades in group 1 significantly differed at 1 year and at final follow-up but did not change in group 2. The number of HIZs significantly decreased in from baseline to 1 year and from baseline to final follow-up in group 1 but did not differ in group 2. CONCLUSION Dynamic lumbar stabilization systems are promising. Observations such as Pfirrmann grade improvements and disappearance of HIZs are concordant with improvements in VAS and ODI scores demonstrate that dynamic stabilization systems may provide an environment for regeneration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Combined Use of a Posterior Dynamic Transpedicular Stabilization System and a Prosthetic Disc Nucleus Device in Treating Lumbar Degenerative Disc Disease With Disc Herniations

BACKGROUND Prosthetic replacement of spinal discs is emerging as a treatment option for degenerative disc disease. Posterior dynamic transpedicular stabilization (PDTS) and prosthetic disc nucleus (PDN) devices have been used sporadically in spinal surgery. METHODS This was a prospective study of 13 patients averaging 40.9 years of age with degenerative disc disease who underwent posterior pl...

متن کامل

Posterior dynamic stabilization for the treatment of patients with lumbar degenerative disc disease: long-term clinical and radiological results.

AIM Comparison of long-term preoperative and postoperative clinical and radiological results for patients diagnosed with degenerative disc disease that underwent posterior dynamic stabilization. Lumbar disc degeneration is caused by a variety of factors. Disruptions in the vertebral endplate result in defects in disc nutrition and, thus, disc degeneration. The aims of dynamic stabilization are ...

متن کامل

Outcome of the L5-S1 segment after posterior instrumented spinal surgery in degenerative lumbar diseases.

BACKGROUND Posterior decompression, instrumentation, and posterolateral fusion are surgical procedures for the treatment of degenerative lumbar diseases. Solid fusion usually causes adjacent problems. This study investigated the clinical outcome and radiographic fate of the L5-S1 segment in patients who underwent posterior instrumented surgery for degenerative lumbar diseases. METHODS From Ja...

متن کامل

Stress Reduction in Adjacent Level Discs via Dynamic Instrumentation: A Finite Element Analysis

BACKGROUND Conventional (rigid) fusion instrumentation is believed to accelerate the degeneration of adjacent discs by increasing stresses caused by motion discontinuity. Fusion instrumentation that employs reduced rod stiffness and increased axial motion, or dynamic instrumentation, may partially alleviate this problem, but the effects of this instrumentation on the stresses in the adjacent di...

متن کامل

Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience

INTRODUCTION The development of adjacent-segment disease is a recognized consequence of lumbar fusion surgery. Posterior dynamic stabilization, or motion preservation, techniques have been developed which theoretically decrease stress on adjacent segments following fusion. This study presents the experience of using a hybrid dynamic stabilization and fusion construct for degenerative lumbar spi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 2015