Acoustic resolution photoacoustic Doppler flowmetry using a transducer array: optimising processing for velocity contrast
نویسندگان
چکیده
This work demonstrates the first measurements of blood flow velocity using photoacoustic flowmetry (PAF) employing a transducer array. The measurements were made in a flow phantom consisting of a tube (580 μm inner diameter) containing blood flowing steadily at physiological speeds ranging from 3 mm/s to 25 mm/s. Velocity measurements were based on the generation of two successive photoacoustic (PA) signals using two laser pulses with a wavelength of 1064 nm; the PA signals were detected using a 64-element transducer array with a -6 dB detection bandwidth of 11-17 MHz. We developed a processing pipeline to optimise a cross-correlation based velocity measurement method comprising the following processing steps: image reconstruction, filtering, displacement detection, and masking. We found no difference in flow detection accuracy when choosing different image reconstruction algorithms (time reversal, Fourier transformation, and delay-and-sum). High-pass filtering and wallfiltering were however found to be essential pre-processing steps in order to recover the correct displacement information. We masked the calculated velocity map based on the amplitude of the cross-correlation function in order to define the region of interest corresponding to highest signal amplitude. These developments enabled blood flow measurements using a transducer array, bringing PAF one step closer to clinical applicability.
منابع مشابه
Acoustic resolution photoacoustic Doppler flowmetry: practical considerations for obtaining accurate measurements of blood flow
An assessment has been made of various experimental factors affecting the accuracy of flow velocities measured using a pulsed time correlation photoacoustic Doppler technique. In this method, Doppler time shifts are quantified via crosscorrelation of pairs of photoacoustic waveforms generated in moving absorbers using pairs of laser light pulses, and the photoacoustic waves are detected using a...
متن کاملPulsed photoacoustic Doppler flowmetry using a cross-correlation method
The feasibility of making spatially resolved measurements of blood flow using pulsed photoacoustic Doppler techniques has been explored. Doppler time shifts were quantified via cross-correlation of pairs of photoacoustic waveforms generated within a blood-simulating phantom using pairs of laser light pulses. The photoacoustic waves were detected using a focussed or planar PZT ultrasound transdu...
متن کاملAcoustic resolution photoacoustic Doppler velocity measurements in fluids using time-domain cross-correlation
Blood flow measurements have been demonstrated using the acoustic resolution mode of photoacoustic sensing. This is unlike previous flowmetry methods using the optical resolution mode, which limits the maximum penetration depth to approximately 1mm. Here we describe a pulsed time correlation photoacoustic Doppler technique that is inherently flexible, lending itself to both resolution modes. Do...
متن کاملB-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum
Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...
متن کاملPulsed photoacoustic Doppler flowmetry using time-domain cross-correlation: accuracy, resolution and scalability.
The feasibility of making spatially resolved measurements of blood velocity using a pulsed photoacoustic Doppler technique in acoustic resolution mode has been investigated. Doppler time shifts were quantified via cross-correlation of photoacoustic waveform pairs generated within a blood-simulating phantom using pairs of light pulses. The phantom comprised micron-scale absorbers imprinted on an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017